• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of cellulose acetate polymer and electrolytic detachable coils for treatment of canine aneurysmal models.

作者信息

Yang Xinjian, Wu Zhongxue, Li Youxiang, Sun Yilin, Yin Ke

机构信息

Beijing Neurosurgical Institute, Beijing 100050.

出版信息

Chin Med Sci J. 2002 Mar;17(1):47-51.

PMID:12894886
Abstract

OBJECTIVE

Electrolytic detachable coils (EDC) have been the main embolic materials for intracranial aneurysms. Liquid aneurysmal embolic materials represented by cellulose acetate polymer (CAP) are still in controversy. In this research, the embolization results and pathological reactions after embolization of canine aneurysmal models with EDC or CAP were observed and compared.

METHODS

The canine aneurysmal models constructed by anastomosis of venous pouches were randomly grouped. The aneurysms were respectively occluded with CAP and electrolytic detachable coils that was named by Wu electrolytic detachable coil (WEDC) and made by us. Angiogram follow-ups were performed at 24-hour, 2-week, and 2-month after embolization. The occluded aneurysms were dissected in each stage for light microscopic, electron microscopic, and histochemical research.

RESULTS

The effect of embolization was significantly better with WEDC than that with CAP (chi2 = 5. 56, P < 0.05). Post-embolized complications such as aneurysm rupture and stenosis of parent arteries could only be found in CAP group. Pathological research showed that CAP mass could packed the aneurysms more densely than coils. Acute chemical damage of aneurysmal wall and inflammatory cell infiltration was prominently found in early stage after CAP-embolization. Organization of thrombus inside aneurysms and formation of endothelial tissue over the orifices of aneurysmal necks could be found in both groups 2 months after embolization. But parts of coils might be exposed outside endothelial layer.

CONCLUSIONS

EDC are still the most safe, efficient, and reliable instruments to embolize aneurysm. CAP should be improved further to solve the problem of strong chemical corrosion and difficulty in control before it is widely used.

摘要

相似文献

1
Comparison of cellulose acetate polymer and electrolytic detachable coils for treatment of canine aneurysmal models.
Chin Med Sci J. 2002 Mar;17(1):47-51.
2
[Re-evaluation of an embolic material for aneurysm cellulose acetate polymer].
Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2000 Oct;22(5):432-5.
3
Randomized comparison of Guglielmi detachable coils and cellulose acetate polymer for treatment of aneurysms in dogs.Guglielmi可脱性弹簧圈与醋酸纤维素聚合物治疗犬动脉瘤的随机对照研究
Stroke. 1998 Feb;29(2):478-85; discussion 485-6. doi: 10.1161/01.str.29.2.478.
4
Direct thrombosis of experimental aneurysms with cellulose acetate polymer (CAP): technical aspects, angiographic follow up, and histological study.
J Neurosurg. 1995 Sep;83(3):531-8. doi: 10.3171/jns.1995.83.3.0531.
5
[Embolization of intracranial aneurysms with new mechanically detachable coils].
Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2002 Oct;24(5):527-9.
6
In vivo embolization of lateral wall aneurysms in canines using the liquid-to-solid gelling PPODA-QT polymer system: 6-month pilot study.应用液-固转化型 PPODA-QT 聚合物栓塞系统栓塞犬侧颅底动脉瘤的体内实验研究:6 个月的初步研究。
J Neurosurg. 2013 Jul;119(1):228-38. doi: 10.3171/2013.3.JNS121865. Epub 2013 Apr 5.
7
Differences in tissue proliferation and maturation between Matrix2 and bare platinum coil embolization in experimental swine aneurysms.实验性猪动脉瘤中Matrix2与裸铂金线圈栓塞在组织增殖和成熟方面的差异。
J Neuroradiol. 2016 Feb;43(1):43-50. doi: 10.1016/j.neurad.2015.04.003. Epub 2015 May 27.
8
Embolization of intracranial aneurysms with second-generation Matrix-2 detachable coils: mid-term and long-term results.颅内动脉瘤的第二代 Matrix-2 可解脱弹簧圈栓塞治疗:中期和长期结果。
J Neurointerv Surg. 2011 Dec 1;3(4):324-30. doi: 10.1136/jnis.2010.004036. Epub 2011 Feb 18.
9
Chinese-made electrolytic detachable coil in the embolization of a dog aneurysmal model.国产电解可脱弹簧圈在犬动脉瘤模型栓塞中的应用
Chin Med J (Engl). 2000 Oct;113(10):921-6.
10
Endovascular treatment of cerebral aneurysms: An in vitro study with detachable platinum coils and tricellulose acetate polymer.脑动脉瘤的血管内治疗:使用可脱卸铂线圈和三醋酸纤维素聚合物的体外研究
AJR Am J Roentgenol. 2001 Jan;176(1):235-9. doi: 10.2214/ajr.176.1.1760235.