Convolution/superposition using the Monte Carlo method.

作者信息

Naqvi Shahid A, Earl Matthew A, Shepard David M

机构信息

Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA.

出版信息

Phys Med Biol. 2003 Jul 21;48(14):2101-21. doi: 10.1088/0031-9155/48/14/305.

Abstract

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The use of explicit photon direction also facilitates modelling of situations where a given voxel is traversed by photons from many directions. Extra-focal radiation, for instance, can therefore be modelled accurately. Our method also allows efficient calculation of a multi-segment/multi-beam IMRT plan by sampling of beam angles and field segments according to their relative weights. For instance, an IMRT plan consisting of seven 14 x 12 cm2 beams with a total of 300 field segments can be computed in 15 min on a single CPU, with 2% statistical fluctuations at the isocentre of the patient's CT phantom divided into 4 x 4 x 4 mm3 voxels. The calculation contains all aperture-specific effects, such as tongue and groove, leaf curvature and head scatter. This contrasts with deterministic methods in which each segment is given equal importance, and the time taken scales with the number of segments. Thus, the Monte Carlo superposition provides a simple, accurate and efficient method for complex radiotherapy dose calculations.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验