Suppr超能文献

一种灵敏且具选择性的液相色谱/电喷雾电离串联质谱分析法,用于同时定量测定血浆中的α-、β-蒿甲醚及其代谢物双氢青蒿素,适用于药代动力学研究。

A sensitive and selective liquid chromatographic/electrospray ionization tandem mass spectrometric assay for the simultaneous quantification of alpha-,beta-arteether and its metabolite dihydroartemisinin in plasma, useful for pharmacokinetic studies.

作者信息

Sabarinath S, Rajanikanth M, Madhusudanan K P, Gupta R C

机构信息

Pharmacokinetics and Metabolism Division, Central Drug Research Institute, Lucknow 226001, India.

出版信息

J Mass Spectrom. 2003 Jul;38(7):732-42. doi: 10.1002/jms.487.

Abstract

A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.

摘要

建立了一种灵敏、选择性好、特异性强且快速的液相色谱/电喷雾电离串联质谱分析方法,并进行了验证,该方法以β-蒿甲醚的丙醚类似物(PE)为内标,用于同时定量猴血浆中的α-、β-蒿甲醚(α-、β-AE)及其代谢产物α-二氢青蒿素(DHA)。该方法采用己烷进行简单的两步液-液萃取。分析物在C(18)反相色谱柱上用甲醇-醋酸铵缓冲液(pH 4)(92:8,v/v)等度洗脱进行色谱分离,并在多反应监测模式下通过质谱分析。色谱运行时间为7分钟,加权(1/x(2))校准曲线在0.78 - 200 ng ml(-1)范围内呈线性。该方法在准确性、精密度、绝对回收率、冻融稳定性、台式稳定性和再进样重现性方面进行了验证。所有分析物在猴血浆中的检测限和定量下限分别为0.39和0.78 ng ml(-1)。批内和批间精密度和准确性均在可接受范围内(<15%)。所有三种分析物即使经过三次冻融循环仍稳定(偏差<15%)。作为内标的α-、β-AE、DHA和PE从加标血浆样品中的平均绝对回收率分别为85.85 +/- 6.56、70.10 +/- 7.06、54.37 +/- 3.39和93.90 +/- 6.9%。本文所述的分析方法可用于研究恒河猴中α-、β-AE和DHA的药代动力学。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验