Abstract

OBJECTIVES

Polymorphonuclear (PMN) cell count in ascitic fluid is the most useful test for the diagnosis of spontaneous bacterial peritonitis (SBP). We evaluated the validity of an automated blood cell counter for the PMN determination in ascitic fluid by comparing it with the traditional hematologic method with a light microscope in a manual counting chamber.

METHODS

A total of 130 ascitic fluid samples were collected from 74 consecutive cirrhotics. The agreement between the two techniques was assessed according to Bland and Altman's method. The sensitivity, specificity, and positive and negative predictive values of the automated blood cell counter were calculated by considering the diagnosis of SBP as a PMN count > or = 250 cells/mm(3), determined by the manual method as the "gold standard."

RESULTS

The mean PMN counts assessed by the manual method and the automated blood cell counter were 124 +/- 301 cells/mm(3) and 130 +/- 339 cells/mm(3), respectively (p = 0.89, ns). The mean +/- SD of the difference between manual and automated measurements was 6 +/- 61 cells/mm(3), whereas the limits of agreement were +127 cells/mm(3) (95% CI = +108 to +147) and -115 cells/mm(3) (95%CI = -96 to -135). SBP was diagnosed in 11 patients. All but one were correctly identified with the automated blood cell counter, with a sensitivity of 94% and a specificity of 100%; positive and negative predictive values were 100% and 99.1%, respectively.

CONCLUSIONS

The manual method and the automated blood cell counter have a good agreement in the PMN determination in ascitic fluid, and the automated blood cell counter is a reliable tool for rapid diagnosis of SBP.

摘要

目的

腹水多形核(PMN)细胞计数是诊断自发性细菌性腹膜炎(SBP)最有用的检查。我们通过将自动血细胞计数器与传统的在手工计数室中使用光学显微镜的血液学方法进行比较,评估了其在腹水PMN测定中的有效性。

方法

从74例连续的肝硬化患者中收集了130份腹水样本。根据Bland和Altman方法评估两种技术之间的一致性。以手工方法确定的PMN计数>或=250个细胞/mm³作为“金标准”来计算自动血细胞计数器的敏感性、特异性以及阳性和阴性预测值。

结果

手工方法和自动血细胞计数器评估的PMN平均计数分别为124±301个细胞/mm³和130±339个细胞/mm³(p = 0.89,无统计学意义)。手工测量与自动测量之间差异的平均值±标准差为6±61个细胞/mm³,而一致性界限为+127个细胞/mm³(95%CI = +108至+147)和-115个细胞/mm³(95%CI = -96至-135)。11例患者被诊断为SBP。除1例患者外,自动血细胞计数器正确识别了所有患者,敏感性为94%,特异性为100%;阳性和阴性预测值分别为100%和99.1%。

结论

手工方法和自动血细胞计数器在腹水PMN测定方面具有良好的一致性,并且自动血细胞计数器是快速诊断SBP的可靠工具。