In vivo evaluation of the biocompatibility of the totally implantable ventricular assist device (HeartSaver VAD).

作者信息

Mussivand Tofy, Harasaki Hiroaki, Litwak Kenneth, Slaughter Mark S, Gray Laman A, Dowling T Robert D, Mueller Ruedi, Masters Roy G, Hendry Paul J, Beck-Da-silva Luís, Davies Ross, Haddad Haissam, Mesana Thierry G, Keon Wilbert J

机构信息

University of Ottawa Heart Institute, Ottawa, Ontario, Canada.

出版信息

ASAIO J. 2003 Jul-Aug;49(4):459-62.

PMID:12918591
Abstract

A series of multicenter in vivo studies have been conducted to assess the biocompatibility and device performance of the HeartSaver VAD, a totally implantable pulsatile ventricular assist device (VAD). The experiments (n = 23) were conducted in calves with a mean weight of 101 (75-152) kg. Implants took place at four centers using two different surgical procedures of implantation (one with cardiopulmonary bypass and one without). Three anticoagulation regimens were used (one with continuous intravenous heparin, one with oral warfarin, and one with oral warfarin combined with antiplatelet clopidogrel therapy). Device function and biochemistry were monitored during the study, and organs and device analysis were conducted at explant. There were six nonsurvivors because of early surgical complications (during the first week of support). The postoperative courses in the remaining 17 (74%) calves were uneventful. Hemodynamic and biocompatibility indicators were monitored throughout the study. The mean duration of device support for those cases was 48 (13-92) days. Mean device flow was 7.15 (+/- 1.68) L/min. There were no deaths caused by infection; however, two animals developed endocarditis believed to be caused by the percutaneous instrumentation lines used for the study. No severe bleeding requiring reoperation occurred during the study. The mean plasma free hemoglobin was within normal limits at 6.8 +/- 2.6 mg/dl. Renal and hepatic functions were normal with a mean creatinine of 0.6 +/- 0.1 mg/dl and a mean aspartate aminotransferase of 68.7 +/- 42.6 mg/dl. Several device related improvements were identified and have now been implemented. Additional bovine implants with an optimized device are currently underway in preparation for human trials.

摘要

相似文献

1
In vivo evaluation of the biocompatibility of the totally implantable ventricular assist device (HeartSaver VAD).
ASAIO J. 2003 Jul-Aug;49(4):459-62.
2
Preclinical readiness testing of the Arrow International CorAide left ventricular assist system.
Ann Thorac Surg. 2004 Jun;77(6):2103-10. doi: 10.1016/j.athoracsur.2003.07.048.
3
Current status on the development of a totally implantable biventricular assist device: the Baylor Gyro BVAD.
Thorac Cardiovasc Surg. 2004 Feb;52(1):1-5. doi: 10.1055/s-2004-815796.
4
Survival for up to six months in calves supported with an implantable axial flow ventricular assist device.使用植入式轴流心室辅助装置支持的小牛存活长达六个月。
ASAIO J. 1997 Jul-Aug;43(4):311-5.
5
Miniaturized HIA microdiagonal pump as left ventricular assist device in a sheep model.小型化HIA微对角泵作为绵羊模型中的左心室辅助装置
ASAIO J. 2008 May-Jun;54(3):233-6. doi: 10.1097/MAT.0b013e318175258e.
6
Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.一种用于桥接应用中为期一个月支持的一次性磁悬浮离心血泵的开发:体外和初步体内评估。
Artif Organs. 2009 Sep;33(9):704-13. doi: 10.1111/j.1525-1594.2009.00900.x.
7
Retrospective analysis of adverse events in preclinical ventricular assist device experiments.临床前心室辅助装置实验中不良事件的回顾性分析。
ASAIO J. 2008 Jul-Aug;54(4):347-50. doi: 10.1097/MAT.0b013e31817d92a8.
8
In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods.Nimbus轴流心室辅助系统的体内评估。标准与方法。
ASAIO J. 1993 Jul-Sep;39(3):M231-6.
9
Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation.EVAHEART心室辅助装置的临床前生物相容性评估:涂层比较与血小板活化
J Biomed Mater Res A. 2007 Apr;81(1):85-92. doi: 10.1002/jbm.a.31006.
10
Results of a multicenter clinical trial with the Thoratec Implantable Ventricular Assist Device.使用Thoratec植入式心室辅助装置的多中心临床试验结果。
J Thorac Cardiovasc Surg. 2007 Jun;133(6):1573-80. doi: 10.1016/j.jtcvs.2006.11.050.

引用本文的文献

1
Biochemical evaluation of an artificial anal sphincter made from shape memory alloys.形状记忆合金制成的人工肛门括约肌的生化评估
J Artif Organs. 2007;10(4):223-7. doi: 10.1007/s10047-007-0395-y. Epub 2007 Dec 20.
2
Development of mechanical circulatory support devices at the University of Tokyo.东京大学机械循环支持设备的研发
J Artif Organs. 2007;10(2):60-70. doi: 10.1007/s10047-006-0368-6. Epub 2007 Jun 20.