Morris Norman, Gass Gregory, Thompson Martin, Conforti David
School of Physiotherapy and Exercise Science, Griffith University, 9726 Gold Coast, Queensland, Australia.
Eur J Appl Physiol. 2003 Nov;90(5-6):620-5. doi: 10.1007/s00421-003-0918-z. Epub 2003 Aug 16.
We investigated the physiological responses in older men to continuous (CEx) and intermittent (IEx) exercise. Nine men [70.4 (1.2) years, VO(2peak): 2.21 (0.20) l min(-1); mean (SE)] completed eight exercise tests (two CEx and six IEx) on an electronically braked cycle ergometer in random order. CEx and IEx were performed at 50% and 70% VO(2peak). IEx was performed using 60sE:60sR, 30sE:30sR and 15sE:15sR exercise to rest ratios. The duration of exercise was adjusted so that the total amount of work completed was the same for each exercise test. Oxygen uptake ( VO(2)), minute ventilation ( V(E)) and heart rate (HR) were measured at the mid-point of each exercise test. Arterialised blood samples were obtained at rest and during exercise and analysed for pH and PCO(2). At the same relative intensity (50% or 70% VO(2peak)), IEx resulted in a significantly lower ( P<0.01) VO(2), V(E) and HR than CEx. There were no significant differences ( P>0.05) in VO(2), V(E) and HR measured at the mid point of the three exercise to rest ratios at 50% and 70% VO(2peak). pH and PCO(2) during CEx and IEx at 50% VO(2peak) were not significantly different from rest. CEx performed at 70% VO(2peak) resulted in significant decreases ( P<0.05) in pH and PCO(2). There was a significant decrease ( P<0.05) in pH only during the 60sE:60sR IEx at 70% VO(2peak). Changes in arterialised PCO(2) during the 60sE:60sR, 30sE:30sR and 15sE:15sR at both 50% and 70% VO(2peak) exercise tests were not significant. When exercising at the same percentage of VO(2peak) and with the total amount of work fixed, IEx results in significantly lower physiological responses than CEx in older men. All results are given as mean (SE).
我们研究了老年男性对持续运动(CEx)和间歇运动(IEx)的生理反应。九名男性[70.4(1.2)岁,峰值摄氧量(VO₂peak):2.21(0.20)升/分钟;均值(标准误)]在电子制动的自行车测力计上以随机顺序完成了八项运动测试(两项CEx和六项IEx)。CEx和IEx分别在50%和70%VO₂peak强度下进行。IEx采用60秒运动:60秒休息、30秒运动:30秒休息和15秒运动:15秒休息的运动与休息比例进行。调整运动持续时间,以使每次运动测试完成的总工作量相同。在每项运动测试的中点测量摄氧量(VO₂)、分钟通气量(V̇E)和心率(HR)。在休息时和运动期间采集动脉化血样,分析pH值和二氧化碳分压(PCO₂)。在相同相对强度(50%或70%VO₂peak)下,IEx导致的VO₂、V̇E和HR显著低于CEx(P<0.01)。在50%和70%VO₂peak下,三种运动与休息比例的中点测量的VO₂、V̇E和HR无显著差异(P>0.05)。50%VO₂peak下CEx和IEx期间的pH值和PCO₂与休息时无显著差异。70%VO₂peak下进行的CEx导致pH值和PCO₂显著降低(P<0.05)。仅在70%VO₂peak下的60秒运动:60秒休息IEx期间pH值有显著降低(P<0.05)。在50%和70%VO₂peak运动测试的60秒运动:60秒休息、30秒运动:30秒休息和15秒运动:15秒休息期间,动脉化PCO₂的变化不显著。当以相同百分比的VO₂peak运动且总工作量固定时,IEx导致老年男性的生理反应显著低于CEx。所有结果均以均值(标准误)表示。