• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Efficacy and tolerance of 2 new percutaneous vena cava filters. A prospective study in 80 patients].

作者信息

Schleich J M, Laurent M, Le Helloco A, Gras D, Lucas C, Langella B, Mabo P, Bédossa M, Pasquali V

机构信息

Service de cardiologie B, hôpital Hôtel-Dieu, Rennes.

出版信息

Arch Mal Coeur Vaiss. 1992 Oct;85(10):1435-41.

PMID:1297292
Abstract

Eighty consecutive patients with an average age of 66.5 +/- 16 years were reviewed 3 and 9 months after implantation of two new percutaneous vena caval filters (Filcard, Cardial) in order to evaluate their efficacy and tolerance. The indications were: a contra-indication to anticoagulants in 19 cases, recurrent pulmonary embolism under anticoagulant therapy in 22 patients, chronic cor pulmonale in 4 patients; finally, in 35 cases, the filter was implanted prophylactically for a "floating" or extensive ilio-caval thrombosis under anticoagulant therapy or in high risk patients: severe cardio-pulmonary failure, malignant disease, massive pulmonary embolism with a contra-indication to fibrinolytic therapy. All implantations were performed by the jugular approach with no local or general complications apart from one pericaval haematoma with a favourable outcome. Cavography and opacification of the renal veins was carried out systematically during implantation. All patients underwent clinical examination, antero-posterior and lateral X rays of the filter, pulmonary scintigraphy, antero-posterior and lateral cavography, a CT scan of the filter, Doppler ultrasonography and rheoplethysmography of the legs 3 months after implantation. At 9 months, clinical examination, abdominal X rays and rheoplethysmography were repeated. There was 100% follow-up at 3 and 9 months. The complications observed at 3 and 9 months were: 5 cases of malposition (6%), 3 recurrent pulmonary emboli (4%), 9 recurrent venous thromboses (13%), 4 vena caval thromboses (5.7%), 7 thrombi caught in the filter (10%), 27 perforations of the vena cava (38%), 3 over 30 degrees tilts of the filter (4%) and 22 migrations (31%).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[Efficacy and tolerance of 2 new percutaneous vena cava filters. A prospective study in 80 patients].
Arch Mal Coeur Vaiss. 1992 Oct;85(10):1435-41.
2
[Very long-term outcome of 68 vena cava filters percutaneously implanted].68枚经皮植入的腔静脉滤器的超长期随访结果
Arch Mal Coeur Vaiss. 2002 Jan;95(1):38-44.
3
[Temporary caval filters. Our experience. Preliminary analysis of 24 cases].[临时性腔静脉滤器。我们的经验。24例初步分析]
Phlebologie. 1993 Jul-Sep;46(3):457-66.
4
[Indications of partial interruption of the inferior vena cava in pulmonary embolism].
Arch Mal Coeur Vaiss. 1995 Nov;88(11 Suppl):1785-91.
5
[Experiences with temporary vena cava filters in 114 at-risk patients with thrombosis or thromboembolism].[114例有血栓形成或血栓栓塞风险患者使用临时腔静脉滤器的经验]
Dtsch Med Wochenschr. 1999 Mar 19;124(11):307-13. doi: 10.1055/s-2007-1024299.
6
[Percutaneously implanted permanent vena cava filter: follow-up of 117 consecutive patients].经皮植入永久性腔静脉滤器:117例连续患者的随访
Rofo. 1997 Sep;167(3):289-96. doi: 10.1055/s-2007-1015533.
7
The Jonas study: evaluation of the retrievability of the Cordis OptEase inferior vena cava filter.乔纳斯研究:Cordis OptEase下腔静脉滤器可回收性评估
J Vasc Interv Radiol. 2005 Nov;16(11):1439-45; quiz 1445. doi: 10.1097/01.RVI.0000171699.57957.C7.
8
[Management of the venous pole in pulmonary embolism].[肺栓塞中静脉端的管理]
Arch Mal Coeur Vaiss. 1995 Nov;88(11 Suppl):1781-4.
9
[Suprarenal inferior vena cava filters. Retrospective review of 30 cases].[肾上腺下腔静脉滤器。30例回顾性研究]
Rev Med Chil. 2008 Dec;136(12):1535-41. Epub 2009 Mar 23.
10
[Vena cava filter -- is there an indication for implantation?].
Zentralbl Chir. 2005 Jun;130(3):250-4. doi: 10.1055/s-2005-836525.