Kohn W G, Ship J A, Atkinson J C, Patton L L, Fox P C
Clinical Investigations and Patient Care Branch, National Institute of Dental Research, National Institutes of Health, Bethesda, Maryland 20892.
J Oral Pathol Med. 1992 Feb;21(2):70-4. doi: 10.1111/j.1600-0714.1992.tb00982.x.
Sequential salivary gland scintigraphy with 99mTc-technetium pertechnetate (Tc-99) is a safe, minimally invasive test for study of major salivary glands. However, its relationship to salivary function has not been investigated in detail. We have investigated the relationship between major salivary gland flow rates and Tc-99 scans and developed a new rating scale using scans of a control group with normal salivary function. Salivary flow rates and Tc-99 scans were obtained from healthy, non-medicated subjects (n = 33) and from xerostomic patients (n = 22). There were significant differences between the groups for salivary flow rates and Tc-99 ratings. Significant correlations were found between salivary flow rates and Tc-99 ratings in the control and xerostomic groups. The Tc-99 rating scale proved reliable in assessing salivary dysfunction, and showed a high inter-examiner correlation. These results demonstrate the usefulness of salivary gland scintigraphy in assessing major salivary gland flow rates and the utility of a new rating scale.
用高锝酸盐(Tc-99)进行的唾液腺序贯闪烁扫描是一种用于研究主要唾液腺的安全、微创检查。然而,其与唾液功能的关系尚未得到详细研究。我们研究了主要唾液腺流速与Tc-99扫描之间的关系,并利用唾液功能正常的对照组扫描结果制定了一种新的评分量表。从健康、未用药的受试者(n = 33)和口干患者(n = 22)获取唾液流速和Tc-99扫描结果。两组之间在唾液流速和Tc-99评分方面存在显著差异。在对照组和口干组中,唾液流速与Tc-99评分之间存在显著相关性。Tc-99评分量表在评估唾液功能障碍方面被证明是可靠的,并且显示出较高的检查者间相关性。这些结果证明了唾液腺闪烁扫描在评估主要唾液腺流速方面的有用性以及一种新评分量表的实用性。