Suppr超能文献

正常渗透和异常渗透对电解质溶液在带电膜上产生的渗透效应的贡献。

The contributions of normal and anomalous osmosis to the osmotic effects arising across charged membranes with solutions of electrolytes.

作者信息

GRIM E, SOLLNER K

出版信息

J Gen Physiol. 1957 Jul 20;40(6):887-99. doi: 10.1085/jgp.40.6.887.

Abstract

The osmotic effect arising across a porous membrane separating the solution of an electrolyte from water (or a more dilute solution) is ordinarily due to both normal osmosis, as it occurs also with non-electrolytes, and to "anomalous" osmosis. It is shown that the normal osmotic component cannot be measured quantitatively by the conventional comparison with a non-electrolytic reference solute. Anomalous osmosis does not occur with electroneutral membranes. Accordingly, with membranes which can be charged and discharged reversibly (without changes in geometrical structure), such as many proteinized membranes, the osmotic effects caused by an electrolyte can be measured both when only normal osmosis arises (with the membrane in the electroneutral state) and when normal as well as anomalous osmosis occurs (with the membrane in a charged state). The difference between these two effects is the true anomalous osmosis. Data are presented on the osmotic effects across an oxyhemoglobin membrane in the uncharged state at pH 6.75 and in two charged states, positive at pH 4.0 and negative at pH 10.0, with solutions of a variety of electrolytes using a concentration ratio of 2:1 over a wide range of concentrations. The rates of the movement of liquid across the membrane against an inconsequentially small hydrostatic head are recorded instead of, as conventional, the physiologically less significant pressure rises after a standard time.

摘要

在将电解质溶液与水(或更稀的溶液)分隔开的多孔膜两侧产生的渗透效应,通常既源于正常渗透(非电解质溶液也会发生),也源于“异常”渗透。结果表明,正常渗透成分无法通过与非电解质参比溶质的传统比较来进行定量测定。电中性膜不会发生异常渗透。因此,对于能够可逆充电和放电(几何结构不变)的膜,比如许多蛋白化膜,当仅出现正常渗透时(膜处于电中性状态)以及当正常渗透和异常渗透都发生时(膜处于带电状态),都可以测量电解质引起的渗透效应。这两种效应的差值就是真正的异常渗透。本文给出了在pH 6.75的不带电状态以及pH 4.0呈正电和pH 10.0呈负电的两种带电状态下,通过多种电解质溶液、浓度比为2:1且浓度范围很宽时,氧合血红蛋白膜两侧的渗透效应数据。记录的是液体在无关紧要的小静水压头作用下穿过膜的速率,而不是像传统那样记录在标准时间后生理意义较小的压力升高值。

相似文献

4
Mechano-chemical effects in weakly charged porous media.弱荷多孔介质的机械化学效应。
Adv Colloid Interface Sci. 2015 Aug;222:779-801. doi: 10.1016/j.cis.2014.09.006. Epub 2014 Oct 2.
6
Asymmetry of diffusion permeability of bi-layer membranes.双层膜扩散渗透性的不对称性。
Adv Colloid Interface Sci. 2008 Jun 22;139(1-2):29-44. doi: 10.1016/j.cis.2008.01.009. Epub 2008 Feb 7.

本文引用的文献

1
Permeability.渗透性
Annu Rev Physiol. 1949;11:545-64. doi: 10.1146/annurev.ph.11.030149.002553.