MILLER J N, BOAK R A, CARPENTER C M
Calif Med. 1958 Apr;88(4):297-9.
A comparative study of the specificity of the Reiter protein complement fixation (RPCF) test and the Treponema pallidum immobilization (TPI) test on 180 sera showed that the results in 178 instances or 98.9 per cent were in agreement. The sensitivity of the RPCF test, when compared to the TPI test, on 189 sera from patients known to have syphilis was in agreement in 182 or 96.3 per cent, assuming a correlation exists between positive TPI and both the "reactive" or "weakly reactive" RPCF test results. As to reproducibility of results, the RPCF test results agreed in 84 of the 87 sera tested (95.4 per cent). The sera were tested at least three times on different days. Anticomplementary reactions were observed in three of 91 normal sera.
一项针对180份血清的赖特蛋白补体结合试验(RPCF)和梅毒螺旋体制动试验(TPI)特异性的对比研究表明,在178例(即98.9%)中结果一致。将RPCF试验与TPI试验相比,在已知患有梅毒的189例患者的血清中,若假定TPI阳性与RPCF试验“反应性”或“弱阳性”结果之间存在相关性,则有182例(即96.3%)结果一致。至于结果的可重复性,在87份受试血清中有84份(95.4%)的RPCF试验结果一致。这些血清在不同日期至少检测了三次。在91份正常血清中有3份观察到了抗补体反应。