Vergniol J C, Bruno R, Montay G, Frydman A
Rhône-Poulenc Rorer Recherche Developpement, Institut de Biopharmacie, Antony, France.
J Chromatogr. 1992 Nov 6;582(1-2):273-8. doi: 10.1016/0378-4347(92)80333-l.
A rapid, selective and reproducible high-performance liquid chromatographic (HPLC) method with ultraviolet detection was developed for the determination of the anti-cancer agent Taxotere in biological fluids. The method involves a solid-phase extraction step (C2 ethyl microcolumns) using a Varian Advanced Automated Sample Processor (AASP) followed by reversed-phase HPLC. The validated quantitation range of the method is 10-2500 ng/ml in plasma with coefficients of variation < or = 11%. The method is also suitable for the determination of Taxotere in urine samples under the same conditions. The method was applied in a phase I tolerance study of Taxotere in cancer patients, allowing the pharmacokinetic profile of Taxotere to be established.