活动响应式起搏系统中活动参数变化的发生率及时间

Incidence and timing of activity parameter changes in activity responsive pacing systems.

作者信息

Ahern T, Nydegger C, McCormick D J, Maquilan M, Schuster M, Kutalek S P

机构信息

Cardiac Electrophysiology Laboratory, Hahnemann University, Philadelphia, Pennsylvania.

出版信息

Pacing Clin Electrophysiol. 1992 May;15(5):762-70. doi: 10.1111/j.1540-8159.1992.tb06843.x.

Abstract

The incidence and timing of rate response parameter reprogramming in activity responsive pacing systems during the year after implantation was evaluated in two groups of patients: 24 patients in whom a VVI,R system was implanted (Activitrax, Medtronic, Inc.), and 21 patients in whom a DDD,R system was implanted (Synchrony, Siemens Pacesetter, Inc.). Activity parameter changes in Activitrax patients were made based on the presence of symptoms, while in Synchrony patients, changes were based on objective data obtained using a sensor indicated rate histogram with a slow and fast walk protocol. No significant difference in the incidence of activity parameter reprogramming was noted at various time intervals during the first year in Activitrax patients; in Synchrony patients a greater incidence of reprogramming changes was noted at the 1-month follow-up visit compared to later follow-up visits (P less than 0.02). Further, the incidence of changes at 1 month was greater for Synchrony compared to Activitrax patients (P less than 0.001), while no difference was detected between groups at subsequent follow-up intervals. Use of the slow and fast walk protocol, by permitting serial evaluation of sensor response, demonstrated alterations in sensor drive rates with similar levels of activity over the initial 4 to 6 postimplant weeks. This may result from postoperative changes at the pacemaker insertion site. Based on this experience, predischarge programming may not predict long-term rate response requirements. We recommend evaluation of sensor function using an exercise protocol performed at 4 to 6 postimplant weeks in all rate responsive pacing systems that utilize a piezoelectric crystal.

摘要

在两组患者中评估了植入后一年内活动感应起搏系统中速率反应参数重新编程的发生率和时间

24例植入VVI,R系统的患者(Activitrax,美敦力公司)和21例植入DDD,R系统的患者(Synchrony,西门子起搏器公司)。Activitrax患者的活动参数根据症状进行更改,而Synchrony患者的更改则基于使用带有慢速和快速步行方案的传感器指示速率直方图获得的客观数据。Activitrax患者在第一年的不同时间间隔内,活动参数重新编程的发生率没有显著差异;在Synchrony患者中,与后期随访相比,在1个月随访时重新编程更改的发生率更高(P小于0.02)。此外,Synchrony患者在1个月时的更改发生率高于Activitrax患者(P小于0.001),而在随后的随访间隔中两组之间未检测到差异。通过允许对传感器反应进行系列评估的慢速和快速步行方案,在植入后的最初4至6周内,在相似的活动水平下显示出传感器驱动速率的改变。这可能是由于起搏器插入部位的术后变化。基于此经验,出院前编程可能无法预测长期的速率反应需求。我们建议在所有使用压电晶体的速率反应起搏系统中,在植入后4至6周使用运动方案评估传感器功能。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验