Clinical experience with Sensolog 703: a new activity sensing rate responsive pacemaker.

作者信息

Lau C P, Tse W S, Camm A J

机构信息

Department of Cardiological Sciences, St. George's Hospital Medical School, London, England.

出版信息

Pacing Clin Electrophysiol. 1988 Oct;11(10):1444-55. doi: 10.1111/j.1540-8159.1988.tb04994.x.

DOI:10.1111/j.1540-8159.1988.tb04994.x
PMID:2462222
Abstract

Sensolog 703 is a new activity sensing rate responsive pacemaker which detects body vibration during physical exercise and uses the vibration as an indicator of the physiological need for a rate increase. This pacemaker was implanted in 11 patients with complete heart block and atrial arrhythmias. Their mean age was 58 (range 39-72) years. With appropriate rate response, exercise capacity, as assessed by the duration of graded treadmill exercise using the Bruce protocol, was significantly improved over the VVI pacing mode (mean +/- SEM, 462 +/- 52 s in the rate responsive mode and 368 +/- 34 s in the VVI mode, P less than 0.02). Cardiac output at peak exercise, as assessed by continuous wave Doppler sampling of aortic root blood flow, was also significantly increased compared to the resting value in both piecing modes. However, the increase was more marked when exercise was performed in the rate response mode (93 +/- 22% increase over resting cardiac output in the rate responsive mode and 57 +/- 13% increase in the VVI mode, P less than 0.05). The rate responses of this pacemaker were compared with those of a Medtronic Activitrax pacemaker. Although both pacemakers responded to an increase in walking speed, neither responded appropriately to walking up different gradients, In both cases, ascending and descending four flights of stairs resulted in similar pacing rates. There was no response to physiological activities with minimal body movements such as isometric exercise and the Valsalva maneuver. Technical problems were encountered in two implanted Sensolog pacemakers: one had spontaneous rate acceleration at rest immediately following implantation and one showed intermittent rate acceleration while the patient was at rest. Both units were programmed to the VVI mode. In conclusion, satisfactory rate response, improvement in exercise duration and increase in cardiac output were achieved with the Sensolog 703 pacemaker. However, as body vibration is not closely related to physiological needs, it has similar limitations in rate response as the Activitrax pacemaker.

摘要

相似文献

1
Clinical experience with Sensolog 703: a new activity sensing rate responsive pacemaker.
Pacing Clin Electrophysiol. 1988 Oct;11(10):1444-55. doi: 10.1111/j.1540-8159.1988.tb04994.x.
2
Limitations of rate response of an activity-sensing rate-responsive pacemaker to different forms of activity.
Pacing Clin Electrophysiol. 1988 Feb;11(2):141-50. doi: 10.1111/j.1540-8159.1988.tb04535.x.
3
Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers.在次极量运动时,房室同步起搏相比频率应答式起搏具有更优的心脏血流动力学:活动感知型DDDR起搏器的观察结果
Pacing Clin Electrophysiol. 1990 Dec;13(12 Pt 2):1832-7. doi: 10.1111/j.1540-8159.1990.tb06899.x.
4
Is accurate rate response programming necessary?
Pacing Clin Electrophysiol. 1990 Aug;13(8):1031-44. doi: 10.1111/j.1540-8159.1990.tb02150.x.
5
Reliability of minute ventilation as a parameter for rate responsive pacing.分钟通气量作为频率适应性起搏参数的可靠性。
Pacing Clin Electrophysiol. 1989 Feb;12(2):321-30. doi: 10.1111/j.1540-8159.1989.tb02665.x.
6
A comparative evaluation of a minute ventilation sensing and activity sensing adaptive-rate pacemakers during daily activities.
Pacing Clin Electrophysiol. 1989 Sep;12(9):1514-21. doi: 10.1111/j.1540-8159.1989.tb06156.x.
7
Role of left ventricular function and Doppler-derived variables in predicting hemodynamic benefits of rate-responsive pacing.左心室功能及多普勒衍生变量在预测频率应答性起搏血流动力学益处中的作用
Am J Cardiol. 1988 Nov 1;62(13):906-11. doi: 10.1016/0002-9149(88)90891-0.
8
Selective vibration sensing: a new concept for activity-sensing rate-responsive pacing.选择性振动传感:一种用于活动感知频率适应性起搏的新概念。
Pacing Clin Electrophysiol. 1988 Sep;11(9):1299-309. doi: 10.1111/j.1540-8159.1988.tb03992.x.
9
Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing.通过活动感知起搏器经皮触发传统植入式脉冲发生器以预测频率应答起搏有效性的实用性。
Am J Cardiol. 1988 Nov 1;62(13):901-5. doi: 10.1016/0002-9149(88)90890-9.
10
Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers.六种频率适应性右心室心脏起搏器的运动性能比较。
Am J Cardiol. 1989 Apr 1;63(12):833-8. doi: 10.1016/0002-9149(89)90052-0.

引用本文的文献

1
Is VVI pacing outmoded?VVI 起搏是否已过时?
Br Heart J. 1992 Apr;67(4):285-8. doi: 10.1136/hrt.67.4.285.