Pancreatic juices were collected by selective reverse catherism of the chief pancreatic duct in two patients, one free from pancreatic disease and the other having a pancreas cancer. They were analysed in detail especially in order to get information on the mechanism of enzyme excretion. The variations of the digestive enzyme activities (amylase, lipase, trypsin, chymotrypsin, carboxypeptidase A and B) were not superimposable among them or with the fluctuations of the protein concentration in the pancreatic juice samples. These results agree with a non-parallel enzyme-excretion mechanism by the pancreas. However deep electrophoresis analyses of pancreatic juice samples showed that the ratio of each digestive enzyme concentration remained almost constant in the same patient. This observation disagrees with the above conclusion and suggests that the data obtained by using classical methods for estimating digestive enzyme activities have to be considered prudently. By another way, two main significant differences were reported by analysing the ionic composition of the pancreatic juice samples following their origin. The pancreatic juice samples of the patient having a pancreas cancer had a lower and more variable Na+ concentration than those coming from the patient who was free from pancreas disease. They had a HCO3- concentration which was almost constant, contrary to what was observed for the pancreatic juice secreted by the other patient.

摘要

通过对两名患者的主胰管进行选择性逆行插管收集胰液,一名患者无胰腺疾病,另一名患有胰腺癌。对胰液进行了详细分析,特别是为了获取有关酶排泄机制的信息。消化酶活性(淀粉酶、脂肪酶、胰蛋白酶、糜蛋白酶、羧肽酶A和B)的变化在两者之间或与胰液样本中蛋白质浓度的波动均无法叠加。这些结果与胰腺的非平行酶排泄机制一致。然而,对胰液样本的深度电泳分析表明,同一患者中每种消化酶浓度的比例几乎保持恒定。这一观察结果与上述结论不一致,并表明使用经典方法估算消化酶活性所获得的数据必须谨慎考虑。另一方面,通过分析胰液样本的离子组成,根据其来源报告了两个主要的显著差异。患有胰腺癌患者的胰液样本中Na+浓度低于且比无胰腺疾病患者的胰液样本更具变异性。它们的HCO3-浓度几乎恒定,这与另一名患者分泌的胰液情况相反。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验