Suppr超能文献

前臂屈肌和腿部伸肌的积分肌电图(IEMG)与扭矩关系的线性和可靠性。

Linearity and reliability of the IEMG v torque relationship for the forearm flexors and leg extensors.

作者信息

Weir J P, Wagner L L, Housh T J

机构信息

Center For Youth Fitness and Sport Research, University of Nebraska, Lincoln 68588-0229.

出版信息

Am J Phys Med Rehabil. 1992 Oct;71(5):283-7. doi: 10.1097/00002060-199210000-00006.

Abstract

The purpose of this investigation was to examine the linearity and reliability of the surface integrated electromyogram (IEMG) v isometric torque relationship for the leg extensors and forearm flexors. Nine men and four women (mean age +/- SD = 22 +/- 2 yr) volunteered for this investigation. Isometric testing was conducted on a Cybex II isokinetic dynamometer with the lever arm at 0.785 rad (45 degrees) below the horizontal plane for the leg extensors and in the vertical plane for the forearm flexors. Bipolar surface electrodes were used to record IEMG values from the vastus lateralis and biceps brachii. To examine test-retest reliability, two test sessions, separated by a minimum of 48 h, were performed. The test-retest linearity of the IEMG v torque relationship ranged from r2 = 0.77 to 0.96 and 0.55 to 0.94 for the forearm flexors and r2 = 0.81 to 0.98 and 0.83 to 0.98 for the leg extensors. The slope values were not significantly different (P > 0.05) between sessions and were correlated (intraclass correlation coefficients) at R = 0.86 (standard error of estimate (SEE) = 5.77 microV.Nm-1, 31% of the mean) and R = 0.97 (SEE = 0.27 microV.Nm-1, 12% of the mean) for the forearm flexors and leg extensors, respectively. The test-retest maximal torque values were 57.73 +/- 22.57 Nm and 58.14 +/- 22.81 Nm (R = 0.99; SEE = 2.39 Nm) for the forearm flexors and 187.79 +/- 55.98 Nm and 195.42 +/- 56.27 Nm (R = 0.96; SEE = 22.62 Nm) for the leg extensors (nonsignificant differences; P > 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是检验腿部伸肌和前臂屈肌的表面整合肌电图(IEMG)与等长扭矩关系的线性度和可靠性。9名男性和4名女性(平均年龄±标准差=22±2岁)自愿参与本研究。在Cybex II等速测力计上进行等长测试,腿部伸肌的杠杆臂位于水平面以下0.785弧度(45度)处,前臂屈肌的杠杆臂位于垂直平面内。使用双极表面电极记录股外侧肌和肱二头肌的IEMG值。为了检验重测可靠性,进行了两个测试环节,间隔至少48小时。前臂屈肌IEMG与扭矩关系的重测线性度范围为r2 = 0.77至0.96和0.55至0.94,腿部伸肌为r2 = 0.81至0.98和0.83至0.98。各环节之间的斜率值无显著差异(P>0.05),前臂屈肌和腿部伸肌的类内相关系数分别为R = 0.86(估计标准误差(SEE)= 5.77微伏·牛顿米-1,占平均值的31%)和R = 0.97(SEE = 0.27微伏·牛顿米-1,占平均值的12%)。前臂屈肌的重测最大扭矩值分别为57.73±22.57牛顿米和58.14±22.81牛顿米(R = 0.99;SEE = 2.39牛顿米),腿部伸肌为187.79±55.98牛顿米和195.42±56.27牛顿米(R = 0.96;SEE = 22.62牛顿米)(无显著差异;P>0.05)。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验