Suppr超能文献

维持性血液透析患者的离子钙浓度

Ionized calcium concentration in maintenance hemodialysis patients.

作者信息

Carney S L

机构信息

Faculty of Medicine, University of Newcastle, Australia.

出版信息

Clin Nephrol. 1992 Sep;38(3):167-70.

PMID:1395172
Abstract

Since numerous formulae for "adjusted" total calcium and "calculated" ionized calcium are used in clinical practice, serum total and ionised calcium concentrations were measured in 20 hemodialysis patients with a wide range of serum total calcium and albumin concentrations. Patients were evaluated pre- and post-dialysis to document the effect of pH. Pre-dialysis total calcium varied from 1.70 to 3.17 mmol/L (mean 2.52 +/- 0.08) and a very close correlation between total and ionized calcium was found (r = 0.842; p less than 0.001) with 50.2% being in the ionized form. Dialysis did not alter this relationship despite a significant increase in pH (0.09; p less than 0.01). A normal volunteer group also demonstrated a similar correlation between total and ionized calcium and while the non-ionized calcium concentration was positively and significantly correlated to the serum albumin concentration (r = 0.629; p less than 0.01) this was not the case in the dialysis patients, although the serum albumin range was much greater (18 to 46 g/L). These results suggest that the percentage of total calcium in the ionized form in dialysis patients is not different from the normal population and that minor changes in pH and albumin may not be as important as has previously been believed. While direct measurement is preferable, halving of the total calcium is a simple prediction of the ionized fraction.

摘要

由于临床实践中使用了多种“校正”总钙和“计算”离子钙的公式,我们对20名血液透析患者的血清总钙和离子钙浓度进行了测量,这些患者的血清总钙和白蛋白浓度范围较广。在透析前后对患者进行评估,以记录pH值的影响。透析前总钙浓度在1.70至3.17mmol/L之间(平均2.52±0.08),发现总钙与离子钙之间存在非常密切的相关性(r = 0.842;p < 0.001),其中50.2%为离子形式。尽管pH值显著升高(0.09;p < 0.01),透析并未改变这种关系。一个正常志愿者组也显示出总钙与离子钙之间存在类似的相关性,虽然非离子钙浓度与血清白蛋白浓度呈正相关且具有显著性(r = 0.629;p < 0.01),但在透析患者中并非如此,尽管血清白蛋白范围要大得多(18至46g/L)。这些结果表明,透析患者中离子形式的总钙百分比与正常人群并无差异,并且pH值和白蛋白的微小变化可能不像以前认为的那么重要。虽然直接测量更为可取,但将总钙减半是对离子部分的一个简单预测。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验