Suppr超能文献

Effect of hypothermia on the coagulation cascade.

作者信息

Rohrer M J, Natale A M

机构信息

Division of Vascular Surgery, University of Massachusetts Medical School, Worcester.

出版信息

Crit Care Med. 1992 Oct;20(10):1402-5. doi: 10.1097/00003246-199210000-00007.

Abstract

BACKGROUND AND METHODS

The development of a multifactorial coagulopathy after massive transfusion is a well-recognized clinical problem that is almost always accompanied by hypothermia. The purpose of this study was to investigate the isolated effect of alterations of temperature on the integrity of the coagulation cascade. Prothrombin times and partial thromboplastin times were each performed 15 times on samples of pooled normal plasma at the temperatures of 37 degrees C, 34 degrees C, 31 degrees C, and 28 degrees C, as well as 39 degrees C and 41 degrees C.

RESULTS

Mean prothrombin time results increased from 11.8 +/- 0.3 (SD) secs at 37 degrees C to 12.9 +/- 0.5, 14.2 +/- 0.5, and 16.6 +/- 0.2 secs at 34 degrees C, 31 degrees C, and 28 degrees C, respectively (p < or = .001 for each). Partial thromboplastin time determinations increased from 36.0 +/- 0.7 (SD) secs at 37 degrees C to 39.4 +/- 1.0, 46.1 +/- 1.1, and 57.2 +/- 0.6 secs at 34 degrees C, 31 degrees C, and 28 degrees C, respectively (p < or = .001 for each). Both prothrombin time and partial thromboplastin time determinations were only minimally shortened at hyperthermic temperatures.

CONCLUSIONS

The series of enzymatic reactions of the coagulation cascade are strongly inhibited by hypothermia, as demonstrated by the dramatic prolongation of prothrombin time and partial thromboplastin time tests at hypothermic deviations from normal temperature in a situation where factor levels were all known to be normal. Clinicians who deal with critically ill massively transfused hypothermic patients all recognize the inevitable appearance of a coagulopathy that has a multifactorial origin. Unless specifically considered, the contribution of hypothermia to the hemorrhagic diathesis may be overlooked since coagulation testing is performed at 37 degrees C, rather than at the patient's actual in vivo temperature.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验