采用微电化学流通池,通过高效液相色谱-电化学检测法分析人血浆中的特布他林。

Analysis of terbutaline in human plasma by high-performance liquid chromatography with electrochemical detection using a micro-electrochemical flow cell.

作者信息

Sagar K A, Kelly M T, Smyth M R

机构信息

School of Chemical Sciences, Dublin City University, Ireland.

出版信息

J Chromatogr. 1992 May 20;577(1):109-16. doi: 10.1016/0378-4347(92)80604-o.

Abstract

A high-performance liquid chromatographic method is described for the determination of terbutaline in human plasma in the range 1-35 ng/ml. Detection was achieved using a carbon fibre micro-electrochemical detector and a column-switching system. The microelectrode cell has advantages over conventional glassy carbon electrode-based detection systems in that it is easy to prepare, flexible in its operation and suffers less trouble from problems such as air bubbles and leaks. Furthermore, it has a better detection limit for terbutaline (0.8 ng/ml) to that obtained using a conventional glassy carbon electrode flow detector (2 ng/ml). Sample clean-up was by on-line solid-phase extraction with column switching, providing a method which was sensitive and reproducible, where the mean overall coefficient of variation was 5.60% and drug recovery in excess of 86% at the concentration levels studied.

摘要

描述了一种高效液相色谱法,用于测定人血浆中浓度范围为1 - 35 ng/ml的特布他林。使用碳纤维微电化学检测器和柱切换系统进行检测。与传统的基于玻碳电极的检测系统相比,微电极池具有易于制备、操作灵活、受气泡和泄漏等问题困扰较少的优点。此外,对于特布他林,它的检测限(0.8 ng/ml)优于使用传统玻碳电极流动检测器获得的检测限(2 ng/ml)。通过柱切换进行在线固相萃取来净化样品,提供了一种灵敏且可重复的方法,在所研究的浓度水平下,平均总变异系数为5.60%,药物回收率超过86%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验