Influence of matrix size, vessel shape, vascular diameter, flow velocity, course of vessels on MR angiography.

作者信息

Asai H, Shimamoto K, Ishigaki T, Baldelli V G, Sakuma S, Ikezaki Y, Yoshitome E

机构信息

Department of Radiology, Nagoya University School of Medicine, Japan.

出版信息

Radiat Med. 1992 Jul-Aug;10(4):145-53.

PMID:1410562
Abstract

Basic experiments were done to examine the influence of the extent of curve, direction of flow, vascular diameter, velocity of flow, and course of vessels on MR angiography. In the first experiment, two phantoms were constructed of vinyl tubing, a hairpin type and one with tubes bent to varying degrees. These phantoms were imaged in two matrices, different FOV, and of various velocities with a 1.5 Tesla system. Images of a normal volunteer were also obtained. In studies of the hairpin phantoms, a low intensity artifact appeared at the curve position, and the edge became fuzzy when the flow was perpendicular to the phase encoding direction. These phenomena were more apparent with a smaller matrix, smaller FOV, more gentle angle, larger diameter, and faster flow; in other words the component along the direction was dominant. In the phantom that used bent tubes, another low intensity artifact appeared on the medial side of the outflow portion. The results obtained from the volunteer corresponded well to those from the basic experiments. It was thought that the profile of flow was not well demonstrated due to the coarse matrix. In the second experiment, water flowed at various speeds through three-dimensional phantoms that were made of vinyl tubes of various diameters and directions. The phantoms were imaged with two- and three-dimensional time of flight and phase contrast angiography. The lower limits of detection of the phase contrast method were almost the same. In the coronal plane, the lower limit decreased to 2.5 mm for arteries and 9.5 mm for veins.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Influence of matrix size, vessel shape, vascular diameter, flow velocity, course of vessels on MR angiography.
Radiat Med. 1992 Jul-Aug;10(4):145-53.
2
Automatic model-based contour detection and blood flow quantification in small vessels with velocity encoded magnetic resonance imaging.基于模型的自动轮廓检测与速度编码磁共振成像对小血管血流的定量分析
Invest Radiol. 2003 Sep;38(9):567-77. doi: 10.1097/01.RLI.0000077125.58014.36.
3
Flow phenomena, classification, and clinical aspects of magnetic resonance angiography.
Curr Opin Radiol. 1991 Apr;3(2):188-95.
4
Regularization of flow streamlines in multislice phase-contrast MR imaging.多层相位对比磁共振成像中血流流线的正则化
IEEE Trans Med Imaging. 2003 Jun;22(6):699-709. doi: 10.1109/TMI.2003.814786.
5
Quantitative phase-contrast flow MRI measurements in the presence of a second vessel closely positioned to the examined vessel.在存在与被检查血管紧邻的第二条血管的情况下进行定量相位对比血流磁共振成像测量。
J Magn Reson Imaging. 2006 Feb;23(2):156-62. doi: 10.1002/jmri.20498.
6
Magnetic resonance angiography.
Curr Opin Radiol. 1992 Aug;4(4):102-9.
7
Reconstruction of blood propagation in three-dimensional rotational X-ray angiography (3D-RA).三维旋转X射线血管造影术(3D-RA)中血液传播的重建。
Comput Med Imaging Graph. 2005 Oct;29(7):507-20. doi: 10.1016/j.compmedimag.2005.03.006. Epub 2005 Sep 2.
8
Time-of-flight methods in MR angiography.
Radiol Technol. 1994 Jan-Feb;65(3):159-70; quiz 171-3.
9
Blood flow determinations utilizing digital densitometry.
Acta Radiol. 1987 Sep-Oct;28(5):635-41.
10
[High resolution MR angiography with rephasing and dephasing sequences for selective vascular imaging of arteries and veins].
Digitale Bilddiagn. 1988 Mar;8(1):18-24.