Rieger A, Schön R, Hagen A
Klinik und Poliklinik für Chirurgie, Neurochirurgische Abteilung, Martin-Luther-Universität Halle-Wittenberg.
Zentralbl Neurochir. 1992;53(3):148-51.
A catheter for intracranial pressure monitoring was introduced into the right lateral ventricle in 71 neurosurgical patients. In 63 patients (88.7%) a significant linear relationship was found between the cerebral pulse amplitude (PA) and the mean intracranial pressure (Pm). In 8 patients (11.3%) no linear relationship was established between PA and Pm. PA- and Pm-analyses performed subsequent to these compliance tests are discussed on the basis of the pathophysiology of the intracranial space.
在71例神经外科患者中,将颅内压监测导管插入右侧脑室。63例患者(88.7%)的脑脉搏振幅(PA)与平均颅内压(Pm)之间存在显著的线性关系。8例患者(11.3%)的PA与Pm之间未建立线性关系。根据颅内空间的病理生理学,讨论了在这些顺应性测试之后进行的PA和Pm分析。