Hashim M A, Waterman A E
Department of Veterinary Surgery, University of Bristol, Langford.
Br Vet J. 1992 Sep-Oct;148(5):435-44. doi: 10.1016/0007-1935(92)90030-5.
Fifty DSH cats were studied radiographically and a highly significant linear correlation was found between the length of the oesophagus measured to the diaphragmatic line on the radiographs and the externally measured distance from the lower jaw incisor teeth to the anterior border of the head of 10th rib. A subsequent manometric study utilizing this correlation in 40 cats suggests that the functional lower oesophageal sphincter (LOS) is situated almost at the level of the diaphragm in the cat. Significant differences were found between the length of the LOS in cats anaesthetized with ketamine compared to alphaxalone-alphadolone or xylazine-ketamine-atropine. The mean lengths of the LOS was 1.42 +/- 0.3 cm. The findings of this study indicate that external measurements can be used to position catheters for accurate oesophageal manometry in the cat.