STANWORTH D R, KUHNS W J
Immunology. 1965 Apr;8(4):323-44.
A quantitative examination of various factors influencing the accuracy of the P—K test was undertaken. The skin site on the back of most recipients tested did not contribute significantly to the variance observed. Coefficients of variation of a single P—K test of the order of 10–20 per cent were frequently demonstrable, for weals exceeding 50 mm in area. Linear log(dose)—response relationships were observed below dose levels corresponding to a 1/5 dilution of the sensitizing serum. A ten-fold increase in dose produced an approximately four-fold increase in weal area. Studies of the influence of the timing and siting of allergen-challenge provided a quantitative indication of the rapid and firm attachment of transferred reaginic antibodies to passively sensitized skin sites.
对影响P-K试验准确性的各种因素进行了定量研究。大多数受试接受者背部的皮肤部位对观察到的变异性没有显著影响。对于面积超过50平方毫米的风团,单次P-K试验的变异系数经常可达10%-20%。在对应于致敏血清1/5稀释度的剂量水平以下,观察到线性对数(剂量)-反应关系。剂量增加10倍,风团面积大约增加4倍。对变应原激发的时间和部位影响的研究,定量显示了转移的反应素抗体与被动致敏皮肤部位的快速牢固结合。