临床正常犬中人类与犬用 Schiotz 眼压计换算表的比较。

Comparison of the human and canine Schiotz tonometry conversion tables in clinically normal dogs.

作者信息

Miller P E, Pickett J P

机构信息

Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison 53706.

出版信息

J Am Vet Med Assoc. 1992 Oct 1;201(7):1021-5.

PMID:1429125
Abstract

Intraocular pressure (IOP) was measured in 114 eyes of 57 clinically normal dogs with 2 applanation tonometers (Tono-Pen and Mackay-Marg) and the Schiotz indentation tonometer, using the 5.5- and 7.5-g weights. Significant differences were not detected between measurements obtained with the Tono-Pen and Mackay-Marg tonometers the Mackay-Marg and Schiotz tonometers using either weight and conversion with the human calibration table, or the Tono-Pen and Schiotz tonometers using the 7.5-g weight and the human calibration table. Values obtained by use of the Tono-Pen tonometer were significantly less (P less than 0.005) than values obtained with the Schiotz tonometer when a 5.5-g weight and the human calibration table were used, but the amount was clinically unimportant. Estimates of IOP using the Schiotz tonometer and the canine calibration table, and either the 5.5- or 7.5-g weight were clinically and significantly much higher (P less than 0.0001) than estimates obtained with the Tono-Pen, Mackay-Marg, or Schiotz tonometers, using the human calibration table and either weight. Sixty to 70% of clinically normal dogs had an IOP greater than or equal to 30 mm of Hg when Schiotz scale measurements were converted with the canine conversion table. For clinically normal dogs, the human calibration table was the most clinically useful table for converting Schiotz tonometer measurements to mm of Hg. Normal mean (+/- SD) canine readings with the Schiotz tonometer and the 5.5-g weight was 4.9 +/- 1.5 tonometer scale units (range, 2 to 11; 95% confidence interval, 1.9 to 7.9).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

使用两种压平眼压计(Tono-Pen眼压计和Mackay-Marg眼压计)以及Schiotz压陷式眼压计,采用5.5克和7.5克砝码,对57只临床正常犬的114只眼睛进行了眼压测量。使用Tono-Pen眼压计和Mackay-Marg眼压计测量结果之间,使用任一种砝码并通过人类校准表换算时,Mackay-Marg眼压计和Schiotz眼压计测量结果之间,以及使用7.5克砝码和人类校准表时Tono-Pen眼压计和Schiotz眼压计测量结果之间,均未检测到显著差异。当使用5.5克砝码和人类校准表时,使用Tono-Pen眼压计获得的值显著低于(P<0.005)使用Schiotz眼压计获得的值,但该差异在临床上并不重要。使用Schiotz眼压计和犬用校准表,采用5.5克或7.5克砝码时的眼压估计值,在临床上显著高于(P<0.0001)使用人类校准表和任一种砝码时,用Tono-Pen眼压计、Mackay-Marg眼压计或Schiotz眼压计获得的估计值。当使用犬用换算表换算Schiotz眼压计测量值时,60%至70%的临床正常犬眼压大于或等于30毫米汞柱。对于临床正常犬,人类校准表是将Schiotz眼压计测量值换算为毫米汞柱时临床上最有用的表格。使用Schiotz眼压计和5.5克砝码时,正常犬的平均(±标准差)读数为4.9±1.5眼压计刻度单位(范围为2至11;95%置信区间为1.9至7.9)。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验