Suppr超能文献

在伪均相酶免疫测定中,对丸剂和上清液酶活性之间使用不透液性流体屏障的研究。

Investigation of the use of impermeable fluid barriers between pelleted and supernatant enzyme activity in a pseudohomogeneous enzyme immunoassay.

作者信息

Maguire G A, Horsfield J A

机构信息

Department of Clinical Biochemistry, Addenbrookes Hospital, Cambridge, UK.

出版信息

Ann Clin Biochem. 1992 Sep;29 ( Pt 5):546-50. doi: 10.1177/000456329202900510.

Abstract

We have investigated the feasibility of performing an automated pseudohomogeneous enzyme immunoassay in which a separation step is not apparent to the user. This was achieved using a layer of silicone fluid, which is immiscible with aqueous solutions, as a physical barrier between the pelleted and supernatant enzyme. Initially we produced a manual assay based on the Serozyme T4 assay to demonstrate the feasibility of the approach. This assay showed good precision, parallelism and correlated with 'in house' results on patients' samples. Production of a fully automated assay was made difficult by the design of available equipment but none the less we demonstrated the feasibility of the automated approach by producing a standard curve for T4.

摘要

我们研究了进行自动假均相酶免疫测定的可行性,在该测定中,用户无需进行分离步骤。这是通过使用一层与水溶液不混溶的硅油作为沉淀酶和上清酶之间的物理屏障来实现的。最初,我们基于Serozyme T4测定法开发了一种手动测定法,以证明该方法的可行性。该测定法显示出良好的精密度、平行性,并且与患者样本的“内部”结果相关。现有设备的设计给全自动测定法的开发带来了困难,但尽管如此,我们通过生成T4的标准曲线证明了自动方法的可行性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验