Suppr超能文献

连续测量可提高激光多普勒对烧伤创面评估的准确性。

Serial measurements increase the accuracy of laser Doppler assessment of burn wounds.

作者信息

Mileski W J, Atiles L, Purdue G, Kagan R, Saffle J R, Herndon D N, Heimbach D, Luterman A, Yurt R, Goodwin C, Hunt J L

机构信息

Department of Surgery, The University of Texas Medical Branch, Galveston, Texas 77555-1172, USA.

出版信息

J Burn Care Rehabil. 2003 Jul-Aug;24(4):187-91. doi: 10.1097/01.BCR.0000076091.79370.56.

Abstract

Traditional methods of judging burn depth by clinical evaluation of the wound based on appearance and sensation remain in wide use but are subject to individual variation by examiner. In addition to the clinical difficulties with burn wound management, observer dependency of wound assessment complicates clinical trials of burn wound therapy. A laser Doppler flowmeter with a multichannel probe was used to measure burn wound perfusion as a tool to predict wound outcome. Serial measurement with laser Doppler flowmetry had an 88% specificity and a positive predictive value of 81% for identifying nonhealing wounds. These results suggest that laser Doppler flowmetry is a potentially useful tool for burn wound assessment.

摘要

传统上通过基于伤口外观和感觉的临床评估来判断烧伤深度的方法仍被广泛使用,但会因检查者的个体差异而有所不同。除了烧伤伤口管理存在临床困难外,伤口评估对观察者的依赖性使烧伤伤口治疗的临床试验变得复杂。使用带有多通道探头的激光多普勒血流仪测量烧伤伤口灌注,作为预测伤口愈合结果的一种工具。激光多普勒血流仪的系列测量在识别不愈合伤口方面具有88%的特异性和81%的阳性预测值。这些结果表明,激光多普勒血流仪是一种潜在有用的烧伤伤口评估工具。