对活跃的人体股四头肌同时进行振动肌电图和肌电图的比较研究。

A comparative study of simultaneous vibromyography and electromyography with active human quadriceps.

作者信息

Zhang Y T, Frank C B, Rangayyan R M, Bell G D

机构信息

Department of Electrical and Computer Engineering, University of Calgary, Alta., Canada.

出版信息

IEEE Trans Biomed Eng. 1992 Oct;39(10):1045-52. doi: 10.1109/10.161336.

Abstract

Vibromyographic (VMG) signals, which are low-frequency vibration signals generated during muscle contraction, were studied in comparison with electromyographic (EMG) signals recorded simultaneously during isometric contraction of the human quadriceps muscles. The comparison was accomplished by evaluating the averaged root mean squared (rms) value, mean frequency (MF), and peak frequency (PF) of the VMG and EMG signals for four muscle contraction levels at joint angles of 30 degrees, 60 degrees, and 90 degrees. The four contraction levels, namely 20, 40, 60, and 80% of maximum voluntary contraction (MVC), were estimated and controlled by the torque readings of a Cybex II dynamometer. It was found that the VMG and EMG under the same conditions on the same muscle group are in general equally sensitive to the levels of muscle contraction. Results show that the rms value of the VMG signal increases linearly, in a manner similar to the EMG rms/%MVC relationship, with increasing muscle contraction levels. Furthermore, the study indicates that the averaged MF (6-24 Hz) and PF (9-19 Hz) of the VMG signals are much lower than the MF (75-109 Hz) and PF (40-80 Hz) of the EMG signals. The slopes of MF/%MVC curves for the VMG and EMG are approximately the same for 60 degrees and 90 degrees joint angles (approximately 3.1 Hz per 20% MVC for VMG and approximately 2.6 Hz per 20% MVC for EMG).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

肌振动图(VMG)信号是肌肉收缩过程中产生的低频振动信号,本研究将其与人体股四头肌等长收缩时同步记录的肌电图(EMG)信号进行了比较。通过评估在30度、60度和90度关节角度下,VMG和EMG信号在四个肌肉收缩水平时的平均均方根(rms)值、平均频率(MF)和峰值频率(PF)来完成比较。四个收缩水平分别为最大自主收缩(MVC)的20%、40%、60%和80%,通过Cybex II测力计的扭矩读数进行估计和控制。结果发现,在相同条件下同一肌肉群的VMG和EMG对肌肉收缩水平的敏感度通常相同。结果表明,VMG信号的rms值呈线性增加,与EMG rms/%MVC关系类似,随肌肉收缩水平的增加而增加。此外,研究表明,VMG信号的平均MF(6 - 24 Hz)和PF(9 - 19 Hz)远低于EMG信号的MF(75 - 109 Hz)和PF(40 - 80 Hz)。在60度和90度关节角度下,VMG和EMG的MF/%MVC曲线斜率大致相同(VMG约为每20%MVC 3.1 Hz,EMG约为每20%MVC 2.6 Hz)。(摘要截于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验