Suppr超能文献

电极间距对肱二头肌等速和等长肌肉动作期间肌电图幅度和平均功率频率的影响。

The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii.

作者信息

Beck Travis W, Housh Terry J, Johnson Glen O, Weir Joseph P, Cramer Joel T, Coburn Jared W, Malek Moh H

机构信息

Department of Nutrition and Health Sciences, Human Performance Laboratory, Center for Youth Fitness and Sports Research, University of Nebraska-Lincoln, Lincoln, NE 68588-0229, USA.

出版信息

J Electromyogr Kinesiol. 2005 Oct;15(5):482-95. doi: 10.1016/j.jelekin.2004.12.001. Epub 2005 Feb 24.

Abstract

The purpose of this study was to examine the effects of interelectrode distance (IED) on the absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isokinetic and isometric torque relationships for the biceps brachii muscle. Ten adults [mean+/-SD age=22.0+/-3.4 years] performed submaximal to maximal, isokinetic and isometric muscle actions of the dominant forearm flexors. Following determination of isokinetic peak torque (PT) and the isometric maximum voluntary contraction (MVC), the subjects performed randomly ordered, submaximal step muscle actions in 10% increments from 10% to 90% PT and MVC. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the biceps brachii muscle with IEDs of 20, 40, and 60mm. Absolute and normalized EMG amplitude (muVrms and %max) increased linearly with torque during the isokinetic and isometric muscle actions (r(2) range=0.988-0.998), but there were no significant changes for absolute or normalized EMG MPF (Hz or %max) from 10% to 100% PT and MVC. In some cases, there were significant (p<0.05) differences among the three IED arrangements for absolute EMG amplitude and MPF values, but not for the normalized values. These findings suggested that for the biceps brachii muscle, IEDs between 20 and 60mm resulted in similar patterns for the EMG amplitude or MPF versus dynamic and isometric torque relationships. Furthermore, unlike the absolute EMG amplitude and MPF values, the normalized EMG data were not influenced by changes in IED between 20 and 60mm. Thus, normalized EMG data can be compared among previous studies that have utilized different IED arrangements.

摘要

本研究的目的是探讨电极间距(IED)对肱二头肌等速和等长扭矩关系中绝对和标准化肌电图(EMG)幅度及平均功率频率(MPF)的影响。10名成年人[平均±标准差年龄 = 22.0±3.4岁]对优势前臂屈肌进行了从次最大到最大的等速和等长肌肉动作。在确定等速峰值扭矩(PT)和等长最大自主收缩(MVC)后,受试者以10%的增量从10% PT和MVC到90% PT和MVC进行随机排序的次最大阶梯式肌肉动作。使用电极间距为20、40和60mm的双极电极布置,同时记录肱二头肌上的表面肌电信号。在等速和等长肌肉动作期间,绝对和标准化肌电幅度(μVrms和%max)随扭矩呈线性增加(r²范围 = 0.988 - 0.998),但从10%到100% PT和MVC,绝对或标准化肌电MPF(Hz或%max)无显著变化。在某些情况下,三种电极间距布置的绝对肌电幅度和MPF值存在显著(p<0.05)差异,但标准化值无差异。这些发现表明,对于肱二头肌,20至60mm的电极间距在肌电幅度或MPF与动态和等长扭矩关系方面产生了相似的模式。此外,与绝对肌电幅度和MPF值不同,20至60mm电极间距的变化并未影响标准化肌电数据。因此,标准化肌电数据可在先前使用不同电极间距布置的研究之间进行比较。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验