• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Guidance on internal dose assessments from monitoring data (project IDEAS).

作者信息

Doerfel H, Andrasi A, Bailey M, Berkovski V, Castellani C M, Hurtgen C, Jourdain J R, LeGuen B

机构信息

Forschungszentrum Karlsruhe GmbH, Karlsruhe, Germany.

出版信息

Radiat Prot Dosimetry. 2003;105(1-4):645-7. doi: 10.1093/oxfordjournals.rpd.a006320.

DOI:10.1093/oxfordjournals.rpd.a006320
PMID:14527042
Abstract

Several international inter-comparison exercises on intake and internal dose assessments from monitoring data led to the conclusion that the results calculated by different participants varied significantly, mainly due to the broad variety of methods and assumptions applied in the assessment procedure. Based on these experiences, the need of harmonisation of the procedures has been formulated as an EU research project under the 5th Framework Programme, with the aim of developing general guidelines for standardising assessments of intakes and internal doses. In the IDEAS project, eight institutions from seven European countries are participating, also using inputs from internal dosimetry professionals from across Europe to ensure broad consensus in the outcome of the project. To ensure that the guidelines are applicable to a wide range of practical situations, the first step will be to compile a database on well documented cases of internal contamination. In parallel, an improved version of existing software will be developed and distributed to the partners for further use. Many cases from the database will be evaluated independently by more partners using the same software and the results will be discussed and the draft guidelines prepared. The guidelines will then be revised and refined on the basis of the experiences and discussions of two workshops, and an intercomparison exercise organised in the frame of the project which will be open to all internal dosimetry professionals.

摘要

相似文献

1
Guidance on internal dose assessments from monitoring data (project IDEAS).
Radiat Prot Dosimetry. 2003;105(1-4):645-7. doi: 10.1093/oxfordjournals.rpd.a006320.
2
Internal dosimetry: enhancements in application, update on the IDEA project.
Radiat Prot Dosimetry. 2003;105(1-4):649-52. doi: 10.1093/oxfordjournals.rpd.a006321.
3
General guidelines for the assessment of internal dose from monitoring data: progress of the IDEAS project.
Radiat Prot Dosimetry. 2007;125(1-4):19-22. doi: 10.1093/rpd/ncl132. Epub 2006 Oct 13.
4
Design and implementation of monitoring programmes for internal exposure (project OMINEX).
Radiat Prot Dosimetry. 2003;105(1-4):641-4. doi: 10.1093/oxfordjournals.rpd.a006319.
5
Harmonisation (legal, dosimetric, quality aspects) of individual monitoring, and integration of monitoring for external and internal exposures (EURADOS Working Group).个人监测的协调(法律、剂量学、质量方面)以及外部和内部照射监测的整合(欧洲辐射剂量学学会工作组)
Radiat Prot Dosimetry. 2003;105(1-4):653-6. doi: 10.1093/oxfordjournals.rpd.a006323.
6
Application of IDEAS guidelines: the IDEAS/IAEA intercomparison exercise on internal dose assessment.
Radiat Prot Dosimetry. 2007;127(1-4):317-20. doi: 10.1093/rpd/ncm283. Epub 2007 Jun 11.
7
A structured approach for the assessment of internal dose: the IDEAS guidelines.
Radiat Prot Dosimetry. 2007;127(1-4):303-10. doi: 10.1093/rpd/ncm405. Epub 2007 Oct 12.
8
Individual monitoring for internal exposure in Europe and the integration of dosimetric data.欧洲内部照射的个体监测及剂量学数据整合
Radiat Prot Dosimetry. 2004;112(1):69-119. doi: 10.1093/rpd/nch284.
9
RBDATA-EULEP: providing information to improve internal dosimetry.
Radiat Prot Dosimetry. 2003;105(1-4):633-6. doi: 10.1093/oxfordjournals.rpd.a006317.
10
Implementation of standards for individual monitoring in Europe.欧洲个人监测标准的实施。
Radiat Prot Dosimetry. 2004;112(1):3-44. doi: 10.1093/rpd/nch282.