Effect of manual hyperinflation on haemodynamics in an animal model.

作者信息

Anning Luke, Paratz Jennifer, Wong Wai Pong, Wilson Kathleen

机构信息

Department of Physiotherapy, University of Queensland, Australia.

出版信息

Physiother Res Int. 2003;8(3):155-63. doi: 10.1002/pri.283.

DOI:10.1002/pri.283
PMID:14533371
Abstract

BACKGROUND AND PURPOSE

Manual hyperinflation is a physiotherapy technique that improves static compliance and mobilizes secretions, but has the potential to alter haemodynamic function. The aim of the present study was to investigate the effects of manual hyperinflation on haemodynamic function in a healthy animal model, without the usual confounding effects inherent in an heterogeneous intensive care population.

METHOD

The study used a within-subjects design, in an animal research theatre. Nine healthy sheep (eight Border Leicester, one Merino, mean weight 39.5 kg, standard deviation (SD) 1.6 kg) completed the study. The sheep were induced (thiopentane 15-20 ml), intubated, ventilated and surgically instrumented for an arterial line and pulmonary artery catheter. Anaesthesia was maintained by 1.5% halothane/oxygen. Manual hyperinflation was delivered for two minutes with a Mapleson C circuit, using a peak inspiratory pressure of 35 cmH2O and an inspiratory:expiratory ratio of 2:1.

RESULTS

Mean tidal volume during manual hyperinflation was 294% (SD 22%) of the ventilator tidal volume. A paired Student's t-test demonstrated that cardiac output (thermodilution method) decreased significantly (p < 0.05) and systemic vascular resistance increased significantly (p < 0.01) after manual hyperinflation. A repeated-measures analysis of variance (ANOVA) and a least-significant difference pairwise comparison revealed that mean arterial pressure and pulse pressure decreased significantly during (p < 0.01) and increased significantly (mean arterial pressure, p < 0.05 and mean pulse pressure p < 0.001) after the technique. Pulmonary artery pressure also increased significantly during manual hyperinflation (p < 0.01). There were no significant effects on right atrial pressure, pulmonary artery occlusion pressure or heart rate.

CONCLUSION

Significant haemodynamic changes occurred in this animal model. The increased intrathoracic pressure, applied for an increased period during inspiration, decreased cardiac output with compensatory vasoconstriction evident by the increased systemic vascular resistance and mean arterial pressure. The results suggest that there may be a decrease in cardiac output after increased positive pressure in subjects with normal cardiac and respiratory function.

摘要

相似文献

1
Effect of manual hyperinflation on haemodynamics in an animal model.
Physiother Res Int. 2003;8(3):155-63. doi: 10.1002/pri.283.
2
A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients.人工通气和呼吸机控制性肺膨胀对重症监护病房中机械通气患者静态肺顺应性及痰液生成影响的比较
Physiother Res Int. 2002;7(2):100-8. doi: 10.1002/pri.246.
3
Hemodynamic effects of manual hyperinflation in critically ill mechanically ventilated patients.
Chest. 1994 Oct;106(4):1182-7. doi: 10.1378/chest.106.4.1182.
4
Performance of manual hyperinflation: consistency and modification of the technique by intensive care unit nurses during physiotherapy.手法过度通气的实施:重症监护病房护士在物理治疗期间对该技术的一致性及改进
J Clin Nurs. 2016 Aug;25(15-16):2295-304. doi: 10.1111/jocn.13190. Epub 2016 Apr 27.
5
Manual hyperinflation: consistency and modification of the technique by physiotherapists.手法过度通气:物理治疗师对该技术的一致性和改进
Physiother Res Int. 2001;6(2):106-17. doi: 10.1002/pri.219.
6
Ventilator versus manual hyperinflation in clearing sputum in ventilated intensive care unit patients.在重症监护病房机械通气患者中,使用呼吸机与手动过度充气清除痰液的比较。
Anaesth Intensive Care. 2012 Jan;40(1):142-9. doi: 10.1177/0310057X1204000117.
7
Ventilator hyperinflation determined by peak airway pressure delivered: A randomized crossover trial.根据输送的气道峰值压力确定的通气机过度充气:一项随机交叉试验。
Nurs Crit Care. 2021 Jan;26(1):14-19. doi: 10.1111/nicc.12498. Epub 2020 Jan 19.
8
Comparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients.在人工通气和插管的重症监护患者中,比较不同呼气末正压水平下手动和通气机控制性过度通气的效果。
Heart Lung. 2006 Sep-Oct;35(5):334-41. doi: 10.1016/j.hrtlng.2006.02.003.
9
[Cardiopulmonary effects of CPPV (continuous positive pressure ventilation) and IRV (inverse ratio ventilation) in experimental myocardial ischemia].[持续气道正压通气(CPPV)和反比通气(IRV)对实验性心肌缺血的心肺影响]
Anaesthesist. 1993 Apr;42(4):210-20.
10
Cardiorespiratory consequences of expiratory chest wall compression during mechanical ventilation and severe hyperinflation.机械通气和严重肺过度充气期间呼气时胸壁受压的心肺后果。
Crit Care Med. 1993 Dec;21(12):1908-14. doi: 10.1097/00003246-199312000-00019.

引用本文的文献

1
Acute bag-valve breathing maneuvers plus manual chest compression is safe during stable septic shock: a randomized clinical trial.急性球囊面罩通气操作加胸外按压在感染性休克稳定期是安全的:一项随机临床试验。
Rev Bras Ter Intensiva. 2017 Jan-Mar;29(1):14-22. doi: 10.5935/0103-507X.20170004.
2
Acute effects of physiotherapeutic respiratory maneuvers in critically ill patients with craniocerebral trauma.颅脑创伤危重症患者理疗呼吸手法的急性效应。
Clinics (Sao Paulo). 2013 Sep;68(9):1210-4. doi: 10.6061/clinics/2013(09)06.