Suppr超能文献

韩国女性乳腺摄影平均腺体剂量的剂量学评估:初步报告。

Dosimetric evaluation of the mean glandular dose for mammography in Korean women: a preliminary report.

作者信息

Oh Ki Keun, Hur Jin, Kim Eun-Kyung, Choo Sung Sil

机构信息

Department of Diagnostic Radiology, Research Institute of Radiological Science, Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.

出版信息

Yonsei Med J. 2003 Oct 30;44(5):863-8. doi: 10.3349/ymj.2003.44.5.863.

Abstract

The purpose of this study was to evaluate the thickness of the compressed breast in mediolateral oblique (MLO) and craniocaudal (CC) mammograms, to relate these thickness and breast patterns to mean glandular dose (MGD) in Korean women, and to evaluate the suitability of using the American College of Radiology's Recommendations for Korean women from a quality assurance standpoint. The study population consisted of 92 paired MLO and CC mammograms obtained on one mammographic unit. The digital readouts of compressed breast thickness, applied compression force and tube voltage were recorded. Entrance skin exposure was measured by dosimetry. MGD was calculated by multiplying entrance skin exposure by the exposure-to-absorbed dose conversion factor. The range of breast thickness was 1.3-6.2 cm in CC mammograms with a mean breast thickness of 3.6 cm, and 1.6-6.5 cm in MLO mammograms with a mean breast thickness of 3.9 cm. MGDs in CC and MLO mammograms were 1.77 mSv and 1.88 mSv per view, respectively. Breast composition patterns were divided into 4 groups according to ACR BI-RADS; P1 (n=20), P2 (n=16), P3 (n=48) and P4 (n=8). The MGDs for these groups were: 1.82, 1.84, 1.84, and 1.91 mSv, respectively. When subjects were subdivided by breast thickness into three groups, namely, below 3 cm, 3 cm to 4.2 cm, aaa and above 4.2 cm, the corresponding MGDs were 1.83, 1.86, and 1.91 mSv. According to our initial trial, the mean breast thickness and the MGDs of Korean women are lower than recommended by the American College of Radiology, which are commonly used for quality assurance purposes.

摘要

本研究的目的是评估韩国女性在内外斜位(MLO)和头尾位(CC)乳腺钼靶片中乳腺压缩后的厚度,将这些厚度及乳腺类型与平均腺体剂量(MGD)相关联,并从质量保证的角度评估美国放射学会的建议对韩国女性的适用性。研究人群包括在一台乳腺钼靶设备上获取的92对MLO和CC乳腺钼靶片。记录乳腺压缩厚度、施加的压缩力和管电压的数字读数。通过剂量测定法测量入射皮肤剂量。通过将入射皮肤剂量乘以照射到吸收剂量转换因子来计算MGD。CC乳腺钼靶片中乳腺厚度范围为1.3 - 6.2厘米,平均乳腺厚度为3.6厘米;MLO乳腺钼靶片中乳腺厚度范围为1.6 - 6.5厘米,平均乳腺厚度为3.9厘米。CC和MLO乳腺钼靶片每视图的MGD分别为1.77毫希沃特和1.88毫希沃特。根据美国放射学会(ACR)乳腺影像报告和数据系统(BI-RADS),乳腺组成类型分为4组;P1(n = 20)、P2(n = 16)、P3(n = 48)和P4(n = 8)。这些组的MGD分别为:1.82、1.84、1.84和1.91毫希沃特。当根据乳腺厚度将受试者细分为三组,即低于3厘米、3厘米至4.2厘米以及高于4.2厘米时,相应的MGD分别为1.83、1.86和1.91毫希沃特。根据我们的初步试验,韩国女性的平均乳腺厚度和MGD低于美国放射学会为质量保证目的而通常推荐的数值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验