A computerized peak detection algorithm was used to retrieve new information about changes in the characteristics of renal nerve activity (RNA) with asphyxia in anesthetized cats. The algorithm scanned the series of RNA voltages for significant increases followed by significant decreases in a small cluster of voltage values. Once each synchronized RNA peak had been detected, its corresponding amplitude, width, and peak-to-peak interval were calculated. The peak-to-peak interval showed two rhythms of synchronized discharge: one between 200-500 ms accounting for 38 +/- 3% of intervals and a higher 20-180 ms frequency (52 +/- 5% of intervals). Asphyxia did not change the periodicity distribution despite increases in arterial pressure. The peak amplitude of RNA, reflecting the number of active fibers, was unimodally distributed and was increased 39 +/- 9% with asphyxia. The shape of the distribution was unchanged. The width of the synchronized activity was also unimodally distributed, mean 79 +/- 3 ms, and increased by asphyxia to 99 +/- 5 ms. The results indicate that the control of the periodicity and amplitude of synchronized discharge appear to be independent and are differentially affected by chemoreceptor input.
使用一种计算机化的峰值检测算法来获取有关麻醉猫窒息时肾神经活动(RNA)特征变化的新信息。该算法扫描RNA电压序列,寻找一小群电压值中先显著增加后显著下降的情况。一旦检测到每个同步的RNA峰值,就计算其相应的幅度、宽度和峰峰间期。峰峰间期显示出两种同步放电节律:一种在200 - 500毫秒之间,占间期的38±3%,另一种频率较高,在20 - 180毫秒之间(占间期的52±5%)。尽管动脉压升高,但窒息并未改变周期分布。反映活动纤维数量的RNA峰值幅度呈单峰分布,窒息时增加了39±9%。分布形状未改变。同步活动的宽度也呈单峰分布,平均为79±3毫秒,窒息时增加到99±5毫秒。结果表明,同步放电的周期和幅度控制似乎是独立的,并且受到化学感受器输入的不同影响。