Suppr超能文献

Determination of isosorbide-5-mononitrate in human plasma by high-resolution gas chromatography.

作者信息

Pastera J, Vyslouzil L, Kvetina J

机构信息

Institute of Experimental Biopharmaceutics, Joint Research Center of PRO.MED.CS Praha a.s. and Academy of Sciences of the Czech Republic, Czech Republic.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2004 Feb 5;800(1-2):271-4. doi: 10.1016/j.jchromb.2003.10.069.

Abstract

A method for the determination of isosorbide-5-mononitrate (5-ISMN) in human plasma by capillary gas chromatography with electron-capture detection was developed and applied to clinical samples. 9-Fluorenone was used as an internal standard, ethyl acetate was employed for liquid-liquid extraction. The advantage of the extraction procedure is the possibility of a direct injection of the plasma extract, without solvent removal/reconstitution of the sample. The precision and accuracy of the method were satisfactory in the concentration range 10-1600 ng/ml. The lower limit of quantification was 10 ng/ml.

摘要