Suppr超能文献

慢性导管插入术和自动采血(Accusampler)对雄性大鼠血清皮质酮、粪便免疫反应性皮质酮代谢物及免疫球蛋白A的影响

Impact of chronic catheterization and automated blood sampling (Accusampler) on serum corticosterone and fecal immunoreactive corticosterone metabolites and immunoglobulin A in male rats.

作者信息

Royo F, Björk N, Carlsson H-E, Mayo S, Hau J

机构信息

Division of Comparative Medicine, Department of Neuroscience, Uppsala University, BMC Box 572, 75123 Uppsala, Sweden.

出版信息

J Endocrinol. 2004 Jan;180(1):145-53. doi: 10.1677/joe.0.1800145.

Abstract

Jugular catheters were inserted in nine male rats under general isofluorane anesthesia and the catheters were connected to a commercially available computerized blood sampling device (Accusampler). Blood samples (150 microl) were collected every 4 h during the first 24 h after surgery and every 12 h during the following 72 h until 94 h after surgery, when the animals were killed. All fecal pellets were collected at blood sampling. Serum corticosterone and fecal concentrations of immunoreactive corticosterone metabolites and immunoglobulin A (IgA) were quantified by ELISAs. In blood, high corticosterone concentrations (>200 ng/ml) were recorded in the first samples obtained after surgery, but the concentrations decreased steadily during the day and became cyclical, showing a diurnal variation with high levels during evenings and low levels in the mornings. The automatic blood sampling itself did not result in recordable increases in serum corticosterone concentrations. The time delay between the presence of elevated corticosterone levels in blood and in feces was approximately 12 h. Fecal immunoreactive corticosterone metabolite levels remained elevated during the 94 h study period after surgery. The fecal concentrations of IgA showed substantial between-animal variation and decreased non-significantly after the surgery. Like serum corticosterone, fecal IgA showed a diurnal variation in amounts excreted, in this case with high values in the morning and low values in the evening. The concentrations of fecal corticosterone and IgA were negatively correlated in samples obtained before surgery but no correlation existed after surgery. This indicates that fecal immunoreactive corticosterone metabolites, but not IgA, constitute a good marker of acute stress. For immunoreactive corticosterone metabolites as well as for IgA, the concentration in feces correlated well with total excretion, making single fecal samplings usable as a measure of total secretion.

摘要

在异氟烷全身麻醉下,给9只雄性大鼠插入颈静脉导管,并将导管连接到市售的计算机化血液采样装置(Accusampler)上。术后头24小时内每4小时采集一次血样(150微升),随后72小时内每12小时采集一次,直至术后94小时处死动物。每次采集血样时收集所有粪便颗粒。通过酶联免疫吸附测定法(ELISA)对血清皮质酮、粪便中免疫反应性皮质酮代谢物和免疫球蛋白A(IgA)的浓度进行定量。在血液中,术后首次采集的样本中记录到高皮质酮浓度(>200纳克/毫升),但浓度在白天稳步下降并呈周期性变化,表现出昼夜变化,晚上水平高,早上水平低。自动采血本身并未导致血清皮质酮浓度出现可记录的升高。血液中皮质酮水平升高与粪便中出现该情况之间的时间延迟约为12小时。术后94小时的研究期间,粪便中免疫反应性皮质酮代谢物水平一直升高。粪便中IgA的浓度在动物之间存在显著差异,术后略有下降但无统计学意义。与血清皮质酮一样,粪便中IgA排泄量也呈现昼夜变化,早上值高,晚上值低。术前采集的样本中,粪便皮质酮和IgA的浓度呈负相关,但术后不存在相关性。这表明粪便中免疫反应性皮质酮代谢物而非IgA是急性应激的良好标志物。对于免疫反应性皮质酮代谢物以及IgA,粪便中的浓度与总排泄量相关性良好,使得单次粪便采样可用于衡量总分泌量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验