J Nucl Med. 2004 Jan;45 Suppl 1:25S-35S.

Abstract

UNLABELLED

Since its introduction in 1998, dual-modality PET/CT imaging has received great attention in the medical community. For the first time, patients can be examined with both CT and PET in a single examination. A whole-body survey is the standard mode of acquisition. The CT images are used for anatomic reference of the tracer uptake patterns imaged in PET, as well as for attenuation correction of the PET data. The routine use of CT-based attenuation correction and user preferences for the quality and type of the CT examination have led to the introduction of different PET/CT scanning protocols.

DISCUSSION

Two general approaches to PET/CT imaging can be distinguished today. One uses CT as a fast transmission source with little additional information for anatomic labeling. The other uses CT as a fast transmission source as well as a state-of-the-art diagnostic tool to maximize image quality using optimal acquisition parameters together with oral and intravenous contrast agents. Variations of these approaches share common concerns about image artifacts that result from mismatches in respiration and patient positioning between the CT and the PET examinations. Protocol requirements for the more complex radiologic PET/CT scenario also include alternative contrast application schemes or modifications to the attenuation correction procedure to handle CT contrast agents appropriately.

CONCLUSION

High-quality PET/CT studies can be provided routinely with existing PET/CT technology that is used efficiently by trained and motivated technologists and physicians. Only then will the potential diagnostic benefit of this new imaging modality be explored fully.

摘要

未标注

自1998年引入以来,双模态PET/CT成像在医学界受到了极大关注。患者首次能够在一次检查中同时接受CT和PET检查。全身扫描是标准的采集模式。CT图像用于对PET成像中示踪剂摄取模式进行解剖学参考,以及对PET数据进行衰减校正。基于CT的衰减校正的常规使用以及用户对CT检查质量和类型的偏好导致了不同PET/CT扫描协议的引入。

讨论

如今可以区分两种PET/CT成像的一般方法。一种将CT用作快速透射源,用于解剖标记的附加信息很少。另一种将CT既用作快速透射源,又用作先进的诊断工具,通过使用最佳采集参数以及口服和静脉造影剂来最大化图像质量。这些方法的变体都共同关注由CT和PET检查之间呼吸和患者体位不匹配导致的图像伪影。更复杂的放射学PET/CT场景的协议要求还包括替代造影剂应用方案或对衰减校正程序进行修改,以适当处理CT造影剂。

结论

现有PET/CT技术能够常规提供高质量的PET/CT研究,训练有素且积极性高的技术人员和医生能够有效利用这些技术。只有这样,才能充分探索这种新成像模式的潜在诊断益处。