Suppr超能文献

Detection and characterization of perianal inflammatory disease: accuracy of transperineal combined gray scale and color Doppler sonography.

作者信息

Mallouhi Ammar, Bonatti Hugo, Peer Siegfried, Lugger Petra, Conrad Friedrich, Bodner Gerd

机构信息

Department of Radiology, Innsbruck University Hospital, Innsbruck, Austria.

出版信息

J Ultrasound Med. 2004 Jan;23(1):19-27. doi: 10.7863/jum.2004.23.1.19.

Abstract

OBJECTIVE

To evaluate the accuracy of transperineal gray scale and color Doppler sonography for the detection and characterization of perianal inflammatory disease with surgical correlation.

METHODS

Eighty-seven patients with suspected perianal inflammatory disorders underwent transperineal gray scale and color Doppler sonography with a linear 4- to 7-MHz transducer that was used to scan the entire perianal region for the detection of suspected inflammatory disorders. Each detected inflammatory disorder was evaluated to determine its morphologic characteristics and extent. Color Doppler sonography was applied to assess the presence of increased vascularity in the perianal region. In comparison with surgical findings, the diagnostic performance of transperineal sonography was assessed by means of receiver operating characteristic analysis for lesion detection and the Spearman rho test for lesion characterization. Logistic regression analysis was used to assess whether increased perineal vascularity was a predictive factor of perianal inflammatory disease.

RESULTS

Seventy-seven perianal inflammatory disorders were confirmed in 62 patients. Gray scale sonography achieved a significantly good performance in the detection (area under the curve = 0.86; P < .001) and characterization (r = 0.65; P < .001) of perianal inflammatory disease. For the detection of perianal fistulas and abscesses, sensitivity was 100% for both, and specificity was 100% and 94%, respectively. With the use of color Doppler sonography, the diagnostic confidence increased slightly (area under the curve = 0.89) but significantly (P = .002). Logistic regression analysis identified hypervascularity at the periphery of a perianal lesion as a significant independent predictor of an inflammatory disease.

CONCLUSIONS

Combined gray scale and color Doppler sonography enables a high detectability rate and comprehensive characterization of perianal abscesses and fistulas.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验