Sunami Y, Nagano K, Hara Y, Imai T, Yamamoto S
Acta Med Okayama. 1977 Dec;31(6):383-91.
Operative treatment of fractures of the neck and trochanter of the femur does not always produce a satisfactory result. This is usually due to biomechanical problems with the available internal fixation methods. We studied the anatomy of the neck of the femur by roentgenograms and sectional specimens from 70 cadavers. In addition, various nail-plates were subjected to buckling tests and, by simultaneously attaching a strain-gauge, stress distribution was calculated. The results of these preliminary studies were then used to design a new nail-plate better than those available at present. Testing of this new nail-plate confirmed that it had a strength equal to that of the Holt nail-plate (the strongest of the available nail-plates).
股骨颈和转子骨折的手术治疗并非总能取得令人满意的结果。这通常是由于现有内固定方法存在生物力学问题。我们通过70具尸体的X线片和断层标本研究了股骨颈的解剖结构。此外,对各种钉板进行了屈曲试验,并通过同时连接应变片来计算应力分布。然后,这些初步研究的结果被用于设计一种比目前现有产品更好的新型钉板。对这种新型钉板的测试证实,它的强度与霍尔特钉板(现有钉板中最强的)相当。