Nakaizumi H, Sasaki K, Sakamoto Y
Department of Ophthalmology, Kanazawa Medical University, Ishikawa, Japan.
Ophthalmic Res. 1992;24 Suppl 1:21-5. doi: 10.1159/000267203.
The small axial movement of the anterior surface of implanted intraocular lenses (IOLs) were examined in pseudophakic eyes with one-piece and three-piece IOLs using an anterior eye segment analysis system. The movement was calculated as the distance between the posterior surface of the cornea and the anterior surface of an IOL under a normal pupil size, following the instillation of 1% pilocarpine and 1% cyclopentolate solutions, respectively. The axial movement including movement after instillation of pilocarpine and cyclopentolate was 0.17 +/- 0.06, 0.05 +/- 0.07 and 0.13 +/- 0.06 mm, in phakic eyes and eyes with one-piece and three-piece IOLs, respectively. Image analysis techniques using Scheimpflug images proved its usefulness in the research field of IOL implantation.
使用眼前节分析系统,对植入一体式和三件式人工晶状体(IOL)的假晶状体眼中人工晶状体前表面的微小轴向运动进行了检查。分别滴入1%毛果芸香碱和1%环喷托酯溶液后,在正常瞳孔大小下,将运动计算为角膜后表面与人工晶状体前表面之间的距离。在有晶状体眼、植入一体式人工晶状体的眼和植入三件式人工晶状体的眼中,包括滴入毛果芸香碱和环喷托酯后的轴向运动分别为0.17±0.06、0.05±0.07和0.13±0.06mm。使用Scheimpflug图像的图像分析技术证明了其在人工晶状体植入研究领域的实用性。