Suppr超能文献

年龄相关性白内障患者单片式和三件式人工晶状体囊袋内稳定性的比较:一项随机对照试验。

Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial.

作者信息

Zhong Xiaojian, Long Erping, Chen Wan, Xiang Wu, Liu Zhaochuan, Chen Hui, Chen Jingjing, Lin Zhuoling, Lin Haotian, Chen Weirong

机构信息

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, 510060, China.

出版信息

BMC Ophthalmol. 2016 Jul 8;16:100. doi: 10.1186/s12886-016-0283-4.

Abstract

BACKGROUND

To compare the in-the-bag stability and visual function of single-piece intraocular lenses (IOLs) and three-piece IOLs.

METHODS

A total of 65 patients with age-related cataracts (80 eyes) were enrolled and randomly assigned to receive in-the-bag implantation of either a single-piece IOL (40 eyes) or a three-piece IOL (40 eyes). Follow-up visits were conducted at 1 week, 1 month and 3 months postoperatively. Visual acuity, refraction and total aberration were examined. IOL position stability (including axial movement, decentration and tilt) was measured using a Scheimpflug imaging system.

RESULTS

At the 3-month follow-up visit, single-piece IOLs did not exhibit significant axial movement (0.07 ± 0.30 mm, p = 0.13) compared with their axial position at 1 week postoperatively, whereas three-piece IOLs displayed forward axial movement of -0.22 ± 0.23 mm (p < 0.0001). The mean manifest spherical equivalence (SE) of eyes with single-piece IOL was 0.15 ± 0.18D, whereas in eyes with three-piece IOLs, the mean manifest SE was -0.34 ± 0.15D (p < 0.001). There was no statistically significant difference in IOL decentration, tilt, uncorrected visual acuity, best-corrected visual acuity or total spherical aberration between the two groups.

CONCLUSIONS

Three months after implantation, single-piece IOLs exhibit better axial stability and more stable refractive outcome than three-piece IOLs, but both IOLs perform equally well in terms of decentration, tilt, visual acuity and total aberration.

TRIAL REGISTRATION

ClinicalTrial.gov, NCT02609997 , 11/18/2015, retrospectively registered.

摘要

背景

比较单片式人工晶状体(IOL)和三件式IOL在囊袋内的稳定性及视觉功能。

方法

共纳入65例年龄相关性白内障患者(80只眼),随机分配接受单片式IOL(40只眼)或三件式IOL(40只眼)的囊袋内植入。术后1周、1个月和3个月进行随访。检查视力、屈光和总像差。使用Scheimpflug成像系统测量IOL位置稳定性(包括轴向移动、偏心和倾斜)。

结果

在3个月随访时,与术后1周时的轴向位置相比,单片式IOL未表现出明显的轴向移动(0.07±0.30mm,p=0.13),而三件式IOL表现出-0.22±0.23mm的轴向向前移动(p<0.0001)。植入单片式IOL眼的平均明显球镜等效度(SE)为0.15±0.18D,而植入三件式IOL眼的平均明显SE为-0.34±0.15D(p<0.001)。两组之间IOL偏心、倾斜、未矫正视力、最佳矫正视力或总球差无统计学显著差异。

结论

植入后3个月,单片式IOL比三件式IOL表现出更好的轴向稳定性和更稳定的屈光结果,但两种IOL在偏心、倾斜、视力和总像差方面表现相当。

试验注册

ClinicalTrial.gov,NCT02609997,2015年11月18日,回顾性注册。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2baf/4939005/6172eb99abbf/12886_2016_283_Fig1_HTML.jpg

相似文献

3
Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens.
J Cataract Refract Surg. 2015 Jan;41(1):90-7. doi: 10.1016/j.jcrs.2014.04.030. Epub 2014 Nov 7.
4
Influence of intraocular lens haptic design on refractive error.
J Cataract Refract Surg. 2014 Sep;40(9):1473-8. doi: 10.1016/j.jcrs.2013.12.018.
5
Intraindividual comparison of aspherical and spherical intraocular lenses of same material and platform.
Ophthalmology. 2009 May;116(5):896-901. doi: 10.1016/j.ophtha.2008.11.022.
9
Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism.
Ophthalmology. 2015 Jan;122(1):39-47. doi: 10.1016/j.ophtha.2014.06.027. Epub 2014 Nov 18.
10
[Comparative study of decentration, tilt and visual quality after implantation of aspherical intraocular lenses].
Zhonghua Yan Ke Za Zhi. 2022 Jul 11;58(7):521-528. doi: 10.3760/cma.j.cn112142-20211103-00518.

引用本文的文献

6
Predicting Residual Astigmatism in Cataract Surgery.
Vision (Basel). 2022 Nov 24;6(4):70. doi: 10.3390/vision6040070.
8
Anterior chamber depth - a predictor of refractive outcomes after age-related cataract surgery.
BMC Ophthalmol. 2019 Jun 25;19(1):134. doi: 10.1186/s12886-019-1144-8.
9
Haptic fracture and dislocation of polyimide intraocular lens after neodymium: YAG laser capsulotomy: A case report.
Medicine (Baltimore). 2019 May;98(20):e15720. doi: 10.1097/MD.0000000000015720.

本文引用的文献

1
Femtosecond laser cataract surgery.
Eye Vis (Lond). 2015 Jun 30;2:11. doi: 10.1186/s40662-015-0021-7. eCollection 2015.
2
Increased Difficulties in Managing Stairs in Visually Impaired Older Adults: A Community-Based Survey.
PLoS One. 2015 Nov 6;10(11):e0142516. doi: 10.1371/journal.pone.0142516. eCollection 2015.
3
The myopia boom.
Nature. 2015 Mar 19;519(7543):276-8. doi: 10.1038/519276a.
4
The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses.
Ophthalmology. 2011 Sep;118(9):1724-31. doi: 10.1016/j.ophtha.2011.02.025. Epub 2011 Jun 12.
5
Intraocular lens alignment from purkinje and Scheimpflug imaging.
Clin Exp Optom. 2010 Nov;93(6):400-8. doi: 10.1111/j.1444-0938.2010.00514.x. Epub 2010 Aug 25.
6
Rotational and centration stability of an aspheric intraocular lens with a simulated toric design.
J Cataract Refract Surg. 2010 Sep;36(9):1523-8. doi: 10.1016/j.jcrs.2010.03.047.
7
Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.
J Cataract Refract Surg. 2007 Mar;33(3):418-29. doi: 10.1016/j.jcrs.2006.10.054.
8
Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements.
J Opt Soc Am A Opt Image Sci Vis. 2006 Mar;23(3):509-20. doi: 10.1364/josaa.23.000509.
9
Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye.
Arch Ophthalmol. 2005 Sep;123(9):1226-30. doi: 10.1001/archopht.123.9.1226.
10
Comparison of tilt and decentration of 1-piece and 3-piece hydrophobic acrylic intraocular lenses.
J Cataract Refract Surg. 2005 Feb;31(2):343-7. doi: 10.1016/j.jcrs.2004.06.022.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验