[A mathematical model of the vascular architecture and of the distribution of resistances in the coronary tree].

作者信息

Pelosi G, Saviozzi G, Trivella M G, L'Abbate A

机构信息

Istituto di Fisiologia Clinica del CNR, Pisa.

出版信息

Cardiologia. 1992 Aug;37(8):581-6.

PMID:1486580
Abstract

The architecture and resistance distribution of the coronary arteriolar tree downstream 100 mu diameter vessels are still largely unknown, due to technical difficulties in direct visualization. In this study we propose a mathematical model of the architecture and the single vessel resistance distribution of terminal arteriolar vasculature in the beating dog heart, based on the analysis of embolization-induced changes of total coronary resistance. Coronary embolization was performed by injecting several boluses of 15 mu (6 cases) and 25 mu (6 cases) plastic microspheres into the maximally vasodilated (adenosine infusion) left circumflex artery of the open chest dog. The relation between the number of plastic beads progressively injected to embolize 15 mu and 25 mu vessels and the resulting increase in total coronary resistance (occlusion function) was obtained in each experiment. If we consider a binary symmetric vascular tree with i) equal resistance for vessels of the same branching order and ii) optimal ratio between resistance of parent and daughter vessels at all branching sites, the simulation of embolization in such a system shows that the occlusion function of the terminal vessels N in the linear portion between 0 and N/2 occluded vessels has a slope S' which is 5.6 times lower than the slope S" between N/2 and 3/4 N occluded vessels and 3.6 times lower than the S' of the occlusion function of the preterminal vessels. The occlusion function in our experiments has a ratio S"/S' close to that predicted by the model and a ratio between the S' of the 25 mu and that of 15 mu experiments equal to 4.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
[A mathematical model of the vascular architecture and of the distribution of resistances in the coronary tree].
Cardiologia. 1992 Aug;37(8):581-6.
2
Small artery occlusion: a theoretical approach to the definition of coronary architecture and resistance by a branching tree model.
Microvasc Res. 1987 Nov;34(3):318-35. doi: 10.1016/0026-2862(87)90065-3.
3
Transmural redistribution of coronary resistance during embolization: a clue to intramyocardial small artery architecture.栓塞过程中冠状动脉阻力的跨壁重新分布:心肌内小动脉结构的线索
Microvasc Res. 1990 May;39(3):322-40. doi: 10.1016/0026-2862(90)90046-t.
4
[The effect of maximal vasodilation on the distensibility of the coronary vascular bed].[最大血管舒张对冠状血管床扩张性的影响]
Cardiologia. 1993 May;38(5):305-10.
5
Regulation of coronary blood flow during exercise.运动期间冠状动脉血流的调节。
Physiol Rev. 2008 Jul;88(3):1009-86. doi: 10.1152/physrev.00045.2006.
6
[Investigation of the structure of human coronary vasculature].[人体冠状动脉血管结构的研究]
Biofizika. 2007 Sep-Oct;52(5):924-30.
7
A computer reconstruction of the entire coronary arterial tree based on detailed morphometric data.基于详细形态测量数据对整个冠状动脉树进行的计算机重建。
Ann Biomed Eng. 2005 Aug;33(8):1015-26. doi: 10.1007/s10439-005-5758-z.
8
The pressure-flow relation in the canine coronary artery: combined effects of critical stenosis and intracoronary thrombosis.犬冠状动脉的压力-流量关系:临界狭窄与冠状动脉内血栓形成的联合效应。
Cardiovasc Res. 1995 Nov;30(5):807-14.
9
[Coronary resistance system in evaluation of microvascular dysfunction after intracoronary microembolization: an experimental study].[冠状动脉阻力系统在冠状动脉内微栓塞后微血管功能障碍评估中的应用:一项实验研究]
Zhonghua Yi Xue Za Zhi. 2004 Apr 2;84(7):578-82.
10
Thrombosis in one coronary artery causes generalized coronary vasoconstriction in a dog model of unstable angina.在不稳定型心绞痛犬模型中,一条冠状动脉内的血栓形成会导致全身性冠状动脉血管收缩。
Clin Sci (Lond). 2001 Apr;100(4):405-10.