We evaluated the clinical usefulness of a commercial two-site immunoassay for calcitonin, which is based on two monoclonal antibodies against distinct epitopes of calcitonin. The potential lower detection limit of the assay was 2 ng/l. Inter-assay and intra-assay variation were both < 11%. No cross reaction with calcitonins from different species (salmon and eel calcitonin) was found. Of the various fragments of human calcitonin, only the 11-32 fragment could be detected. Basal calcitonin concentrations in normals (n = 69) ranged from < 2 ng/l to 50 ng/l. Basal calcitonin concentrations in 30% of the men (< 2-48 ng/l) and 51% of the women (< 2-10 ng/l) were undetectable. Stimulation of calcitonin with pentagastrin (0.5 microgram/kg body weight) in normal subjects was followed by an increase in calcitonin in all men (n = 17) and in 60% of the women (n = 12). The upper reference value for pentagastrin-stimulated calcitonin concentrations for all 29 normals was 78 ng/l (defined as the 95th percentile): 79 ng/l for men, and 50 ng/l for women. Using a different immunoradiometric two-site assay, a similar percentage of "positive" responses to pentagastrin in normals was obtained (20 out of 29). Four previously thyroidectomized patients with medullary thyroid carcinoma had normal basal, but pathological stimulated calcitonin values at follow-up. At reoperation, cervical lymph nodes with tumour tissue were removed. Postoperatively, the patients had basal and stimulated calcitonin concentrations within the limits of the established reference range. In conclusion, reference ranges for basal and pentagastrin-stimulated calcitonin concentrations have been established for an immunometric two-site assay.(ABSTRACT TRUNCATED AT 250 WORDS)
我们评估了一种基于针对降钙素不同表位的两种单克隆抗体的市售降钙素双位点免疫测定法的临床实用性。该测定法的潜在下限为2 ng/l。批间和批内变异均<11%。未发现与来自不同物种的降钙素(鲑鱼降钙素和鳗鱼降钙素)有交叉反应。在人降钙素的各种片段中,仅能检测到11 - 32片段。正常人群(n = 69)的基础降钙素浓度范围为<2 ng/l至50 ng/l。30%的男性(<2 - 48 ng/l)和51%的女性(<2 - 10 ng/l)的基础降钙素浓度检测不到。正常受试者经五肽胃泌素(0.5微克/千克体重)刺激后,所有男性(n = 17)和60%的女性(n = 12)的降钙素均升高。29名正常受试者五肽胃泌素刺激后降钙素浓度的上限参考值为78 ng/l(定义为第95百分位数):男性为79 ng/l,女性为50 ng/l。使用不同的免疫放射双位点测定法,正常人群中对五肽胃泌素“阳性”反应的比例相似(29例中有20例)。4例先前接受甲状腺切除术的甲状腺髓样癌患者随访时基础降钙素正常,但刺激后降钙素值异常。再次手术时,切除了有肿瘤组织的颈部淋巴结。术后,患者的基础和刺激后降钙素浓度在既定参考范围内。总之,已为免疫测定双位点测定法建立了基础和五肽胃泌素刺激后降钙素浓度的参考范围。(摘要截断于250字)