Liang F Q, Geasey S D, del Cerro M, Aquavella J V
Cornea Research Laboratory, University of Rochester, NY.
Refract Corneal Surg. 1992 Nov-Dec;8(6):459-65.
The routine technique for evaluating the smoothness of an excimer laser keratectomy has been scanning electron microscopy (SEM). However, this method suffers from tissue shrinkage and surface artifacts, and evaluates the surface only in a qualitative manner. In our study, we used a Zygo microscope to quantitatively assess the smoothness of the excimer laser ablated corneas, without complicated tissue processing.
Five rabbit eyes and five PMMA blocks underwent 193-nanometer excimer laser ablations (5.00-millimeter diameter and 80-micrometer depth). The ablation zones of the corneas were trephined and fixated prior to the measurement. The surface smoothness was measured under the Zygo and characterized by two surface parameters (Ra and RMS). After measurement, the corneal and PMMA samples were processed for SEM.
The Ra and RMS (mean +/- SD) for the ablated corneas are 183.33 +/- 20.6 and 240.06 +/- 23.10 nm, respectively; for the PMMA blocks, 79.49 +/- 23.02 and 96.45 +/- 27.16 nm, respectively. There are significant differences of Ra and RMS between the ablated corneas and PMMA blocks (p < .01), indicating the ablated corneal surfaces are rougher than the ablated PMMA surfaces. Qualitatively, SEM correlated well with the results of the Zygo measurements.
We found this technique to be a simple, accurate, and reproducible means of objectively assessing the surface smoothness following excimer laser ablation. Combined use of the Zygo and SEM enables more complete evaluation of the ablated corneal surface.
评估准分子激光角膜切削术平滑度的常规技术是扫描电子显微镜(SEM)。然而,这种方法存在组织收缩和表面伪像的问题,并且只是以定性方式评估表面。在我们的研究中,我们使用Zygo显微镜定量评估准分子激光切削后的角膜平滑度,无需复杂的组织处理。
对5只兔眼和5个聚甲基丙烯酸甲酯(PMMA)块进行193纳米准分子激光切削(直径5.00毫米,深度80微米)。在测量前,将角膜的切削区域环切并固定。在Zygo显微镜下测量表面平滑度,并通过两个表面参数(粗糙度算术平均偏差Ra和均方根粗糙度RMS)进行表征。测量后,对角膜和PMMA样本进行SEM处理。
切削后的角膜的Ra和RMS(平均值±标准差)分别为183.33±20.6和240.06±23.10纳米;PMMA块的分别为79.49±23.02和96.45±27.16纳米。切削后的角膜和PMMA块之间的Ra和RMS存在显著差异(p <.01),表明切削后的角膜表面比切削后的PMMA表面更粗糙。定性地说,SEM与Zygo测量结果相关性良好。
我们发现该技术是客观评估准分子激光切削后表面平滑度的一种简单、准确且可重复的方法。联合使用Zygo和SEM能够更全面地评估切削后的角膜表面。