Abstract

The authors describe an operational amplifier with an adjustable frequency response and its use in membrane physiology, using the voltage clamp and current clamp method. The amplifier eliminates feedback poles causing oscillation. It consists of a follower with a high input resistance in the form of a tube and of an actual amplifier with an adjustable frequency response allowing the abolition of clicks by one pole and of oscillation by two poles in the 500 Hz divided by infinity range. Further properties of the amplifier: a long-term voltage drift of 1 mv, a temperature voltage drift of 0.5 mv/degrees K, input resistance greater than 1 GOhm, amplification greater than 80 dB, output +/- 12 v, 25 ma, noise, measured from the width of the oscilloscope track in the presence of a ray of normal brightness, not exceeding 50 muv in the 0-250 kHz band, f1 = 1 MHz. A short report on the amplifier was published a few years ago (Gulísek and Hencek 1973).

摘要

作者描述了一种具有可调频率响应的运算放大器及其在膜生理学中的应用,采用电压钳制和电流钳制方法。该放大器消除了导致振荡的反馈极点。它由一个呈电子管形式的具有高输入电阻的跟随器和一个具有可调频率响应的实际放大器组成,该可调频率响应可在500赫兹到无穷大的范围内通过一个极点消除喀哒声,通过两个极点消除振荡。该放大器的其他特性:长期电压漂移为1毫伏,温度电压漂移为0.5毫伏/开尔文度,输入电阻大于1吉欧,放大倍数大于80分贝,输出为±12伏、25毫安,在正常亮度射线存在的情况下,从示波器轨迹宽度测量的噪声在0至250千赫频段不超过50微伏,f1 = 1兆赫。几年前发表了一篇关于该放大器的简短报告(古利塞克和亨内克,1973年)。