Navrátil Tomás, Sebková Svetlana, Kopanica Miloslav
J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejskova 3, 182 23, Prague, Czech Republic.
Anal Bioanal Chem. 2004 May;379(2):294-301. doi: 10.1007/s00216-004-2517-1. Epub 2004 Feb 17.
A new type of silver composite electrode was examined, prepared from silver, graphite powder, and methacrylate resin. The effects of the presence of various cations (cadmium, copper, bismuth, thallium), anions (chlorides), surface-active substances (Triton X-100), and oxygen on the anodic-stripping voltammetric determination of lead were studied. It was found that the effect of underpotential deposition at the composite electrode differs from that produced at a metallic silver electrode, mainly at low concentrations of the deposited metal. The use of this type of silver composite electrode in differential pulse anodic-stripping voltammetry enables direct determination of lead in natural water samples without elimination of surface-active substances (LOD about 3 microg L(-1)).