Hashemi S M, Golnaraghi M F, Patla A E
Department of Mech., Aerospace & Ind. Eng., Ryerson University, Toronto, Canada.
Med Biol Eng Comput. 2004 Jan;42(1):61-70. doi: 10.1007/BF02351012.
A simple approach for the suppression of the tremor associated with Parkinson's disease is presented. The proposed system is a tuned vibration absorber (TVA), which has been very effective in the suppression of vibrations in an experimental model of the human arm with two degrees of freedom. Theoretical and numerical methods were used to study the behaviour of the arm model and to develop an effective tremor reduction approach. Based on these studies, a vibration absorber was designed, tested numerically and fabricated for experimental testing. Experimental investigations indicated that optimum control performance was related to the position of the controller and the excitation frequency. With a distance of 160 mm from the end of forearm, the TVA was found to have the best performance, and, for different tremor frequencies, the vibration of the experimental model was reduced by more than 80%.
本文提出了一种抑制帕金森病相关震颤的简单方法。所提出的系统是一种调谐振动吸收器(TVA),它在抑制具有两个自由度的人体手臂实验模型中的振动方面非常有效。采用理论和数值方法研究手臂模型的行为,并开发一种有效的震颤减少方法。基于这些研究,设计了一个振动吸收器,进行了数值测试并制造出来用于实验测试。实验研究表明,最佳控制性能与控制器的位置和激励频率有关。当距前臂末端160毫米时,发现调谐振动吸收器具有最佳性能,并且对于不同的震颤频率,实验模型的振动减少了80%以上。