Greenspoon Susan A, Ban Jeffrey D, Pablo Lourdes, Crouse Cecelia A, Kist Frank G, Tomsey Chris S, Glessner Alex L, Mihalacki Lisa R, Long Teresa M, Heidebrecht Bruce J, Braunstein Cathryn A, Freeman David A, Soberalski Carl, Nathan Bruesehoff, Amin Ashima S, Douglas Elizabeth K, Schumm James W
Virginia Division of Forensic Science, Richmond, VA 23219, USA.
J Forensic Sci. 2004 Jan;49(1):71-80.
The PowerPlex 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and DS5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus. Amelogenin. The PowerPlex 16 BIO System is optimized for use with the Hitachi FMBIO gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex 16 BIO System provides STR data of a quality comparable with other PowerPlex STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.
PowerPlex 16 BIO复合短串联重复序列(STR)系统包含13个联合DNA索引系统(CODIS)位点(FGA、TPOX、D8S1179、vWA、D18S51、D21S11、TH01、D3S1358、CSF1PO、D16S539、D7S820、D13S317和D5S818),外加两个五核苷酸重复位点(五核苷酸D和五核苷酸E)以及性别鉴定位点牙釉蛋白。PowerPlex 16 BIO系统针对日立FMBIO凝胶成像系统进行了优化。由七个独立实验室组成的一个联盟合作开展了联邦调查局(FBI)标准所定义的用于进行开发验证的研究,包括样本一致性评估、拖尾百分比测定、无证明力案件样本分析、精密度、灵敏度、混合样本测定、底物效应、环境损伤影响以及物种特异性研究。除了弗吉尼亚法医科学部数据库中的一个样本在D13S317位点出现不一致外,所有用于一致性测试的样本结果均一致,该位点的引物序列发生了改变。拖尾值与其他STR复合系统相当,精密度与通过凝胶电泳分析的其他复合系统相当,血液样本所放置的底物对DNA图谱没有影响,为PowerPlex 16 BIO系统重新分型的无证明力案件样本与之前的分型结果一致。当向PowerPlex 16 BIO系统扩增反应中加入超过0.125 ng的DNA时,所有实验室均生成了完整图谱。混合样本研究结果与其他复合系统报告的结果相当,环境研究表明,当样本在高温下长时间孵育时,较大分子量的位点会丢失,并且仅在灵长类动物DNA样本中观察到明显的跨物种杂交。所开展的这项广泛验证工作表明,PowerPlex 16 BIO系统提供的STR数据质量与其他PowerPlex STR复合试剂盒以及其他广泛使用的STR复合系统相当,因此适用于证据案件分析以及数据库样本分型。