Suppr超能文献

[激光诱导荧光检测毛细管电泳灵敏装置的研究及其应用]

[Study on a sensitive setup of capillary electrophoresis with laser induced fluorescence detector and its application].

作者信息

Li Yuan-qian, Yang Jing-guo, Zhou Ying, Zou Xiao-li, Mi Jian-ping, Zeng Hong-yan

机构信息

Department of Sanitary Technology, West China School of Public Health, Sichuan University, Chengdu 610041, China.

出版信息

Sichuan Da Xue Xue Bao Yi Xue Ban. 2004 Jan;35(1):103-6.

Abstract

OBJECTIVE

To develop a setup of capillary electrophoresis with laser induced fluorescence detector for separating and detecting DNA fragments and protein.

METHODS

The setup is assembled of He-Ne Laser with 543.5 nm as the excitation light, filter, monochromator, photomultiplier tube and a computer for controlling the system and collecting the electropherograms.

RESULTS

The design of the setup and the analytical parameters were optimized. The electropherograms with high Signal-to-Noise were obtained by the laser induced fluorescence detector-capillary electrophoretic setup. For Sulforhdamine B, the detection limit was 10(-9) mol/L, and the linear range from 1 x 10(-6) mol/L to 1 x 10(-9) mol/L. The PCR products, the digested products by Hae III and BstE of mycobacterium DNA, and the human serum albumin were determined by the successful application of this setup.

CONCLUSION

The setup is characterized by simple structure, low cost and high sensitivity. Compared with traditional agarose gel electrophoresis, capillary electrophoresis with laser induced fluorescence detector is more remarkable in resolution and detection time. It can be applied as a more effective means for analysis of DNA fragments and protein.

摘要

目的

开发一种带有激光诱导荧光检测器的毛细管电泳装置,用于分离和检测DNA片段及蛋白质。

方法

该装置由以543.5nm作为激发光的氦氖激光器、滤光片、单色仪、光电倍增管以及用于控制系统和采集电泳图的计算机组装而成。

结果

对装置的设计和分析参数进行了优化。通过激光诱导荧光检测器 - 毛细管电泳装置获得了高信噪比的电泳图。对于磺罗丹明B,检测限为10(-9)mol/L,线性范围为1×10(-6)mol/L至1×10(-9)mol/L。通过成功应用该装置测定了PCR产物、分枝杆菌DNA经Hae III和BstE酶切后的产物以及人血清白蛋白。

结论

该装置具有结构简单、成本低和灵敏度高的特点。与传统琼脂糖凝胶电泳相比,带有激光诱导荧光检测器的毛细管电泳在分辨率和检测时间方面更具优势。它可作为分析DNA片段和蛋白质的更有效手段。

相似文献

3
Simple luminescence detector for capillary electrophoresis.
Methods Mol Biol. 2009;503:221-37. doi: 10.1007/978-1-60327-567-5_12.
4
Laser-induced fluorescence detector for liquid chromatography: applications to protein analysis.
Biomed Chromatogr. 2000 May;14(3):156-9. doi: 10.1002/1099-0801(200005)14:3<156::AID-BMC942>3.0.CO;2-X.
5
Determination of riboflavin in urine and beverages by capillary electrophoresis with in-column optical fiber laser-induced fluorescence detection.
J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Sep 1;856(1-2):245-51. doi: 10.1016/j.jchromb.2007.06.011. Epub 2007 Jun 22.
8
In-column fiber-optic laser-induced fluorescence detection for CE.
Electrophoresis. 2007 Aug;28(17):3105-14. doi: 10.1002/elps.200600815.
10
Whole-column fluorescence-imaged capillary electrophoresis.
Electrophoresis. 2004 Nov;25(21-22):3820-4. doi: 10.1002/elps.200406043.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验