Suppr超能文献

门控心脏单光子发射计算机断层扫描与磁共振成像的自动图像配准

Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging.

作者信息

Aladl Usaf E, Hurwitz Gilbert A, Dey Damini, Levin David, Drangova Maria, Slomka Piotr J

机构信息

Department of Diagnostic Radiology and Nuclear Medicine, University of Western Ontario, London, Canada.

出版信息

J Magn Reson Imaging. 2004 Mar;19(3):283-90. doi: 10.1002/jmri.20003.

Abstract

PURPOSE

To develop an automatic registration method for electrocardiogram-gated myocardial perfusion single-photon emission computed tomography (SPECT) and cardiac cine-magnetic resonance imaging (MRI).

MATERIALS AND METHODS

Paired myocardial perfusion SPECT (MPS) and MRI from 20 patients were considered. MR images were presegmented by heart localization based on detection of cardiac motion and optimal thresholding. A registration algorithm based on mutual information was subsequently applied to all time frames or a selected subset from both modalities.

RESULTS

A preprocessing step significantly improved the accuracy of the registration when compared to automatic registration performed without preprocessing. Errors in translation parameters (T(x), T(y), T(z)) averaged (1.0 +/- 1.5, 1.1 +/- 1.3, 0.9 +/- 0.9) pixels with MRI segmentation and (4.6 +/- 3.2, 3.4 +/- 2.6, 3.0 +/- 3.4) pixels without MRI segmentation. Errors in rotation parameters (R(x), R(y), R(z)) averaged (5.4 +/- 2.9, 3.4 +/- 2.7, 4.5 +/- 3.6) degrees with MRI segmentation and (9.3 +/- 6.1, 4.8 +/- 4.3, 14.6 +/- 12.6) degrees without MRI segmentation. Error was calculated as the absolute difference between the expert manual and the automatic registration transformation.

CONCLUSION

Automatic registration of gated MPS and cine MRI is possible with the use of a mutual information-based technique when MR images are presegmented. Cardiac motion can be used to isolate the left ventricle (LV) on the MR images automatically, and subsequently the segmented MR images can be coregistered with gated MPS.

摘要

目的

开发一种用于心电图门控心肌灌注单光子发射计算机断层扫描(SPECT)和心脏电影磁共振成像(MRI)的自动配准方法。

材料与方法

考虑了20例患者的配对心肌灌注SPECT(MPS)和MRI。基于心脏运动检测和最佳阈值化,通过心脏定位对MR图像进行预分割。随后,将基于互信息的配准算法应用于两种模态的所有时间帧或选定子集。

结果

与未进行预处理的自动配准相比,预处理步骤显著提高了配准的准确性。在进行MRI分割时,平移参数(T(x)、T(y)、T(z))的误差平均为(1.0±1.5、1.1±1.3、0.9±0.9)像素,未进行MRI分割时为(4.6±3.2、3.4±2.6、3.0±3.4)像素。旋转参数(R(x)、R(y)、R(z))的误差在进行MRI分割时平均为(5.4±2.9、3.4±2.7、4.5±3.6)度,未进行MRI分割时为(9.3±6.1、4.8±4.3、14.6±12.6)度。误差计算为专家手动配准和自动配准变换之间的绝对差值。

结论

当对MR图像进行预分割时,使用基于互信息的技术可以实现门控MPS和电影MRI的自动配准。心脏运动可用于在MR图像上自动分离左心室(LV),随后分割后的MR图像可与门控MPS进行配准。