Higashida Yoshiharu, Ideguchi Tadamitsu, Muranaka Toru, Tabata Nobuyuki, Miyajima Ryuichi, Akazawa Fumio, Ikeda Hirotaka, Morimoto Ken, Ohki Masafumi, Toyofuku Fukai, Doi Kunio
Department of Radiological Sciences, School of Health Sciences, Faculty of Medicine, Kyushu University.
Nihon Igaku Hoshasen Gakkai Zasshi. 2004 Jan;64(1):35-40.
To demonstrate the clinical usefulness of a temporal subtraction technique for the detection of interval changes in various interstitial lung diseases on digital chest radiographs.
One hundred pairs of chest radiographs in 34 patients (63 with and 37 without interval changes) with various interstitial lung diseases were selected. All cases were confirmed by serial chest computed tomography (CT) and ascertained by radiologists. All chest radiographs were obtained with a computed radiography (CR) system, and temporal subtraction images were produced with an iterative image-warping technique. Four radiologists and two thoracic physicians provided confidence levels for interval changes in interstitial lung diseases with and without temporal subtraction. Their performances with and without temporal subtraction were evaluated by means of receiver operating characteristic (ROC) analysis using a sequential test.
The area under the ROC curve (Az) values of six observers obtained with and without temporal subtraction were 0.90 and 0.78, respectively. Results showed that the detection of interval changes in interstitial lung diseases was significantly improved by the use of temporal subtraction images compared with CR images alone(P = 0.002). Furthermore, the high detection rate was achieved with temporal subtraction images regardless of the subtlety and location of interval changes.
Temporal subtraction improved the diagnostic accuracy of radiologists in detecting interval changes in interstitial lung diseases on chest radiographs. It was also useful for cases of multiple interval changes.
证明时间减影技术在数字胸部X线片上检测各种间质性肺疾病的间隔期变化的临床实用性。
选取34例患有各种间质性肺疾病的患者的100对胸部X线片(63例有间隔期变化,37例无间隔期变化)。所有病例均经胸部计算机断层扫描(CT)系列检查确诊,并由放射科医生确定。所有胸部X线片均使用计算机X线摄影(CR)系统获得,并采用迭代图像变形技术生成时间减影图像。四名放射科医生和两名胸科医生对有和无时间减影的间质性肺疾病的间隔期变化提供置信度。使用序贯检验通过受试者操作特征(ROC)分析评估他们在有和无时间减影情况下的表现。
有和无时间减影时六名观察者的ROC曲线下面积(Az)值分别为0.90和0.78。结果表明,与单独使用CR图像相比,使用时间减影图像可显著提高间质性肺疾病间隔期变化的检测率(P = 0.002)。此外,无论间隔期变化的细微程度和位置如何,时间减影图像都能实现高检测率。
时间减影提高了放射科医生在胸部X线片上检测间质性肺疾病间隔期变化的诊断准确性。它对多个间隔期变化的病例也很有用。