Alió Jorge L, Artola Alberto, Ruiz-Moreno José M, Hassanein Ahmed, Galal Ahmed, Awadalla Mohamed A
Refractive Surgery and Cornea Department, Instituto Oftalmológico de Alicante, Medical School, Miguel Hernández University, Avda. Denia 111, 03015 Alicante, Spain.
Ophthalmology. 2004 Apr;111(4):747-51. doi: 10.1016/j.ophtha.2003.08.024.
To evaluate the outcome and potential reversibility of the changes induced in keratoconic eyes after intracorneal ring segment explantation.
Retrospective, interventional case series.
Five eyes of 4 patients who underwent uneventful implantation of one or two intracorneal ring segment segments for the correction of clear corneal keratoconus and who required explantation of one segment due to complications.
Visual acuity, refraction, keratometric readings, and corneal topography. The follow-up was up to 1 year from the primary implantation procedure in all cases.
Explantation was performed easily in all cases without intraoperative or postoperative complications. The segments were extracted due to migration and local melting. The visual, refractive, and topographic map findings regressed to approximate the original clinical situation before segment implantation.
Intracorneal ring segments are safely and easily explanted from keratoconic eyes. Most of the visual, refractive, and topographic findings return to near the preimplantation levels.
评估角膜内环片取出后圆锥角膜眼所诱导变化的结果及潜在可逆性。
回顾性、干预性病例系列。
4例患者的5只眼,这些患者因矫正透明角膜圆锥角膜而顺利植入一个或两个角膜内环片,且因并发症需要取出其中一个环片。
视力、验光、角膜曲率读数及角膜地形图。所有病例均从初次植入手术起随访1年。
所有病例取出环片操作均顺利,无术中或术后并发症。因环片移位和局部溶解而取出环片。视力、验光及地形图检查结果均恢复至接近环片植入前的原始临床状态。
角膜内环片可安全、轻松地从圆锥角膜眼中取出。大多数视力、验光及地形图检查结果恢复至接近植入前水平。