Postblink changes in total and corneal ocular aberrations.

作者信息

Montés-Micó Robert, Alió Jorge L, Muñoz Gonzalo, Pérez-Santonja Juan J, Charman W Neil

机构信息

Department of Research, Development and Innovation, Instituto Oftalmológico de Alicante, Medical School, Miguel Hernández University, Avda. Denia 111, 03015 Alicante, Spain.

出版信息

Ophthalmology. 2004 Apr;111(4):758-67. doi: 10.1016/j.ophtha.2003.06.027.

Abstract

OBJECTIVE

The purpose of this study was to determine objectively the changes in optical aberrations induced by the progressive tear film irregularity after a blink and their effects on retinal image quality.

DESIGN

Prospective, consecutive, nonrandomized comparative trial (self-controlled).

PARTICIPANTS

Twenty healthy subjects.

MAIN OUTCOME MEASURES

Corneal and total ocular aberrations were determined in 20 subjects at various time intervals (approximately 0, 10, and 20 seconds) after a blink. Corneal and total aberrations were measured with an Orbscan II topographer (Orbtek Inc, Salt Lake City, UT) and a Zywave aberrometer (Bausch & Lomb, Irvine, CA), respectively. All data were decomposed using Zernike polynomials to yield the root mean square wavefront deviations, in micrometers (microm), for different pupil diameters (3.5, 4.5, 5.5, and 6.5 mm). A merit function (Mf), defined as the volume under the 2-dimensional modulation transfer function as computed from the total wavefront error, was taken as the image quality metric.

RESULTS

Both corneal and total aberrations (third order and higher) showed a statistically significant increase with time after the blink for all pupil diameters except 3.5 mm. The magnitude of the increase was greater at larger pupil diameters. For a 6.5-mm pupil, the aberrations increased on average by a factor of 2.5 (total) and 2.5 (corneal). Increases in total aberration were related closely to increases in corneal aberration (P<0.0001). For a 6.5-mm pupil, after 20 seconds, the reduction in optical quality (Mf) among the subjects studied was 21+/-8%.

CONCLUSIONS

After a blink, the gradual increase in optical aberration associated with the increasingly irregular tear film may cause a progressive reduction in the optical quality of the eye. These changes in aberration with time may partly limit the improvements in visual performance that are achievable by customized corneal ablation.

摘要

目的

本研究的目的是客观确定眨眼后泪膜逐渐不规则所引起的光学像差变化及其对视网膜图像质量的影响。

设计

前瞻性、连续性、非随机对照试验(自身对照)。

参与者

20名健康受试者。

主要观察指标

在20名受试者眨眼后的不同时间间隔(约0、10和20秒)测定角膜像差和全眼像差。分别使用Orbscan II角膜地形图仪(Orbtek公司,盐湖城,犹他州)和Zywave像差仪(博士伦公司,尔湾,加利福尼亚州)测量角膜像差和全眼像差。所有数据均使用泽尼克多项式进行分解,以得出不同瞳孔直径(3.5、4.5、5.5和6.5毫米)下的均方根波前偏差,单位为微米(μm)。将一个优值函数(Mf)作为图像质量指标,该函数定义为根据总波前误差计算出的二维调制传递函数下的面积。

结果

除3.5毫米瞳孔外,所有瞳孔直径下,眨眼后角膜像差和全眼像差(三阶及更高阶)均随时间呈统计学显著增加。在较大瞳孔直径时增加幅度更大。对于6.5毫米的瞳孔,像差平均增加了2.5倍(全眼)和2.5倍(角膜)。全眼像差的增加与角膜像差的增加密切相关(P<0.0001)。对于6.5毫米的瞳孔,20秒后,所研究受试者的光学质量(Mf)下降了21±8%。

结论

眨眼后,与泪膜日益不规则相关的光学像差逐渐增加可能会导致眼睛光学质量逐渐下降。这些像差随时间的变化可能会部分限制通过定制角膜消融所能实现的视觉性能改善。